the Thermapen in boiling water but you must first know the correct temperature of boiling 

water at your altitude and at the current atmospheric pressure. A calculator can be found at  

www.thermoworks.com/bpcalc to quickly find that temperature for your zip code.

Instructions to use the Trim Adjust to tune your Thermapen calibration are downloadable from 

the Thermapen Mk4 web page. You should not need to do this under normal use. A complete 

factory re-calibration, including a certificate, is also available from ThermoWorks for a fee.

Intelligent Backlight

When the Thermapen is turned on, a light sensor (small round 

window located just to the right of the main display) continuously 

monitors ambient light levels. As it gets darker, the intelligent 

backlight comes on automatically to read the digits in any light 

condition. Covering the light sensor will also turn on the backlight 

except in well-lit areas. The backlight will remain on for a minimum 

of 10 seconds. If the unit is displaying the low battery symbol, the 

backlight brightness will be reduced to prolong battery life.

Batteries

Each unit includes one pre-installed AAA (1.5V) battery located 

inside the sealed battery compartment. An illuminated battery symbol (

) in the LCD 

display indicates that the battery should be replaced 

soon. The instrument will continue to measure 

accurately, but it is recommended to replace the 

batteries immediately (in low battery condition, 

the backlight brightness will be reduced to prolong 

battery life). Once the battery is too low to display 

readings, the display will be replaced with ‘Flat’ then 

‘Bat’ and then shut down. To continue using the 

instrument, replace the battery.

Replacing the Battery

The battery is pre-installed on your new Thermapen 

Mk4 and should last up to 3,000 hours. Should you 

need to replace the battery, loosen the battery cover 

screw using a Phillips screwdriver to remove the 

battery cover. Pull up on the spring-loaded battery 

clip and tip the unit to allow the battery to slide out. 

Replace with a single AAA battery noting the polarity 

(positive goes in first, retaining clip rests on negative). 

Tighten the battery cover screw until the battery cover 

is snug onto the seal. Do not overtighten. 

Cleaning and Maintenance

To avoid potential bacteria growth and cross-contamination, wipe the probe after each use 

and regularly clean the entire Thermapen body. Oils and grease should be wiped off the body 

and the rotating hub. We recommend sanitizing wipes or a damp paper towel with an anti-

microbial cleaning solution. Protected from dust and immersion in water to 39” depth for up to 

30 minutes. The probe should not be rotated while the body is submerged or under a stream 

of water. Protect the plastic body from high temperatures. DO NOT LEAVE THE THERMAPEN 

IN AN OVEN OR ON A HOT SURFACE. Not dishwasher safe.

Warning

IPA and other solvents may cause damage to the case and screen of this instrument.

Error Messages

•‘Lo’ is displayed if measurements are being made below the instrument range.

•‘Hi’ is displayed if measurements are being made above the instrument range.

•‘Err’ is displayed if the probe develops a fault. Call for details.

For all other error messages, contact ThermoWorks’ Technical Support at 1-800-393-6434 

or [email protected].

Loosen battery screw

Light Sensor

Battery Cover

AAA 1.5V Battery

Retaining clip rests on negative (–) 

end of battery

Summary of Contents for Mk4

Page 1: ...s located at the tip of the probe shaft Minimum immersion is only 1 8 3 mm For best results immerse or penetrate the probe into the food item so the probe tip is in the place you want to measure In food this should normally be at the center of the thickest part The Thermapen will read to within 1 F of the actual temperature of an ice bath within three seconds Reading times in other foods may vary ...

Page 2: ...until SLEEP is shown at the top of the display Press the SET button to step through the sleep interval settings from 10 seconds to 180 seconds in 10 second intervals or to turn the sleep function off Press MENU to store the sleep interval and the unit will enter sleep mode at the specified number of seconds without movement detected END will flash momentarily to show that all settings are saved No...

Page 3: ...hen Bat and then shut down To continue using the instrument replace the battery Replacing the Battery The battery is pre installed on your new Thermapen Mk4 and should last up to 3 000 hours Should you need to replace the battery loosen the battery cover screw using a Phillips screwdriver to remove the battery cover Pull up on the spring loaded battery clip and tip the unit to allow the battery to...

Page 4: ...nts or workmanship The warranty does not cover fair wear and tear abnormal use or storage incorrect use neglect water damage misapplication modification or abuse ThermoWorks reserves the right to evaluate all warranty claims before any action is taken and at its discretion may repair or replace without charge For complete warranty details visit www thermoworks com Thermapen Accessories available a...

Reviews: