- 3 -
1-1 Specifications
MODEL
26
Nominal hourly gas consumption by
proportional electronic gas control
MJ/h
173
Minimum gas supply pressure (Natural Gas)
kPa
1.13
Maximum gas supply pressure (Natural Gas)
kPa
5.0
Minimum gas supply pressure (Propane)
kPa
2.75
Maximum gas supply pressure (Propane)
kPa
7.0
Test point pressure High (Natural Gas)
kPa
0.84
Test point pressure Low (Natural Gas)
kPa
0.16
Test point pressure High (Propane)
kPa
1.27
Test point pressure Low (Propane)
kPa
0.21
Water heating capacity raised 40
°C
L/min
16.25
Minimum working pressure
kPa
115
Maximum working pressure
kPa
1200
Gas injectors diameter (Natural Gas)
mm
1.00 / 1.50
Gas injectors diameter (Propane)
mm
0.7 / 1.0
Input voltage single phase 50Hz
V
240
Maximum output current
A
0.66
Inlet gas connection male thread
R3/4” (20mm)
Cold water connection male thread
R3/4” (20mm)
Hot water connection male thread
R3/4” (20mm)
Relief valve pressure setting
kPa
1400
Weight dry
kg
20.5
Dimensions (DxWxH)
mm
205 x 366 x 573
IAPMO Approval certificate no. GMK10408. Watermark Certificate of compliance WM-000506
1. General Outline of Appliance