- 40 -
- 41 -
Procedure
Illustration
- 40 -
Removing Over Heat Thermostat
(1)
Disconnect the Over Heat Thermostat
connectors (2 pcs).
(2)Pull the Over Heat Thermostat forward.
Removing Water Flow Contorol Valve.
(1)
Remove the setscrew fixing the PCB
case. Lift the case up and pull it out.
(2)Disconnect Water Flow Contorol Valve
8P connector(on PCB side), Water Flow
Sensor 3P relay connector and Incoming
Temperature Sensor connector.
Water Flow Sensor
relay connector
Incomming Temperature
Sensor connector
Quick-fasteners
Water Flow Control Valve
Over Heat Thermostat
Water Flow Contorol
Valve connector
(3)
Remove the 2 quick-fasteners and take
out Water Flow Contorol Valve.