background image

2

www.thermaltronics.com   support email: [email protected]

SAFETY PRECAUTIONS

Warning

A fire may result if this equipment is not used with care and for intended 

applications. To avoid electric shock or injury, please follow the instructions 

below strictly: 

1. The unit must be properly grounded.

2. The unit can reach extremely high temperatures when switched ON.

- Do not use the device near flammable materials or gases

- Do not touch heated parts, which can cause severe burns

- Do not point the nozzle towards any part of the body

3. Never operate the equipment with wet hands.

4. Always disconnect the power cord and allow the unit ample time to 

cooldown before performing maintenance.

5. Use only genuine replacement parts.

Caution

1. Use this equipment in a well-ventilated area, away from combustible 

equipment.

2. Disconnect the power cord if the unit is not used for an extended period of 

time.

3. Place handle in stand when not in use.

4. Handle with care.

- Never drop or sharply jolt the unit.

- The unit contains delicate parts that can be damaged if subjected to 

physical force.

    - Do not spill any liquids into the unit.

5. Do not operate on uneven surfaces.

6. Allow to cool down before storage.

7. Turn off the power when the unit is not in use. 

8. Do not alter the unit in any manner.

9. When resting the handle in the handle holder, make sure there are no 

objects within 30cm of the nozzle, as nearby objects maybe damaged.

10. Do not apply excessive force when installing and removing nozzles.

11. Do not use pliers to pull the edges of the nozzle.

12. Do not over tighten the screw when installing a new nozzle.

Summary of Contents for TMT-HA600 Series

Page 1: ...USER MANUAL TMT HA600 HOT AIR TOOL www thermaltronics com ...

Page 2: ......

Page 3: ...pair or replace it free of charge at its sole option Warranty period is from the date of purchase by the original owner If the date of purchase cannot be substantiated the date of manufacture will be used as the start of the warranty period TABLE OF CONTENTS TMT HA600 SPECIFICATIONS 1 INTRODUCTION 1 SYSTEM FEATURES 1 SAFETY PRECAUTIONS 2 SYSTEM PANEL FRONT PANEL 3 UNPACKING ASSEMBLY OPERATION 4 SY...

Page 4: ...has been tested and inspected by Thermaltronics prior to shipment and with proper maintenance will give you years of reliable performance SYSTEM FEATURES The TMT HA600 hot air tool can be used for surface mount component removal and reflow on components such as SOIC CHIP QFP PLCC and others 1 Digital display shows temperature and status 2 Airflow meter provides visual feedback of air flow 3 1300W ...

Page 5: ...genuine replacement parts Caution 1 Use this equipment in a well ventilated area away from combustible equipment 2 Disconnect the power cord if the unit is not used for an extended period of time 3 Place handle in stand when not in use 4 Handle with care Never drop or sharply jolt the unit The unit contains delicate parts that can be damaged if subjected to physical force Do not spill any liquids ...

Page 6: ...al temperature in Celsius or Fahrenheit b Air Flow Display Shows the air flow c Temperature Control Increase or Decrease the set temperature Temperature Range in Celsius 100C to 480C Temperature Range in Fahrenheit 212F to 896F d Air Flow Control Increase or Decrease the set air flow range 15 99 e Function Button Toggle the hot air tool between standby mode or operating mode In System Settings the...

Page 7: ...he temperature level using the c Temperature Control see Front Panel The a Temperature Display will change from showing the actual temperature to the set temperature while the temperature is being adjusted After temperature adjustment is done the Temperature Display will revert back to showing the actual temperature rather then the display temperature 11 Wait for the actual temperature to reach th...

Page 8: ...emperature scale has been set by the factory For manual override follow the procedure below 1 Follow System Settings Enter Menu procedures 2 Use the d Air Flow Control down button to adjust system selection menu to SEL 2 3 Press the d Air Flow Control up button to confirm the selection 4 The display will show c celsius or f fahrenheit 5 Press the d Air Flow Control up and down buttons to adjust th...

Page 9: ...s damaged replace if damaged Q Temperature display is always above 500 after a few minutes the display shows Off A The thermal sensor may be broken and needs to be replaced Q Replacing the heating element Caution Disconnect power before replacing heater element 1 Remove the three screws holding the heater pipe in place 2 Pull back the air tube from the back of the hot air gun 3 Push forcefully up ...

Page 10: ...6 Nozzle 10 6mm x 10 8mm SOL 14 16 10 6 10 8 HTN SL20 Nozzle 10 6mm x 13 3mm SOL 20 20J 10 6 13 3 HTN SL24 Nozzle 10 6mm x 15 9mm SOL 24 24J 10 6 15 9 HTN SL28 Nozzle 10 6mm x 18 4mm SOL 28 10 6 18 4 HTN SL44 Nozzle 16 0mm x 27 9mm SOL 44 16 0 27 9 HTN SJ32 Nozzle 13 5mm x 20 6mm SOJ 32 13 5 20 6 HTN SJ40 Nozzle 13 5mm x 25 4mm SOJ 40 13 5 25 4 HTN TS24 Nozzle 17 0mm x 7 1mm TSOP 20 24 PIN 17 0 7 ...

Page 11: ...Support Email support thermaltronics com www thermaltronics com ...

Reviews: