Toughpower
CableManagement 1200W ATX12V 2.2 & EPS 12V 2.91 Version
Toughpower
CableManagement 1200W ATX12V 2.2 & EPS 12V 2.91 Version
Please be noticed that when trying to connect more than one
connector to a graphic card, it is strongly recommended to
choose the connectors from exactly the same +12V rail
.
6 pin
6 pin
6 pin
8 pin
8 pin
8 pin
12V3
12V4
X
X
X
X
X
X
7. SPEC Table
Model
W0133
SPECIFICATION
Power
Dimension
Switches
PFC
Cooling System
Noise
P. G. Signal
Efficiency
INPUT
Input Voltage
Input Frequency Range
MTBF
Input Current
Hold-up Time
1200W
200mm(L)x160mm(W)x86mm(H)
ATX Logic on-off additional power rocker switch
Active PFC (PF > 0.9)
140mm Fan, 2300RPM 10%
16 dBA at 1300 RPM
100-500 ms
up to 87%
16ms
115 VAC ~ 230 VAC
47 ~ 63 H z
120,000 hrs minimum (at 25
)
15A
OUTPUT
Max/Min
*1
Regulation
*2
Ripple & Noise
Output
+12V1
+12V4
+12V2
+12V3
+5V
+3.3V
-12V
+5Vsb
Total Power
1200W
20A/1A
+3,-3%
120mV
600W
600W
250W
9.6W
17.5W
120mV
120mV
120mV
50mV
50mV
50mV
120mV
+3,-3%
+3,-3%
+3,-3%
+3,-3%
+3,-3%
+3,-5%
+10,-10%
36A/1A
20A/1A
36A/1A
30A/0.5A
30A/0.5A
0.8A/0A
3.5A/0A
*1. +5Vsb operate at 3.5A max load base on PS-ON mode. If PS-OFF +5Vsb only operate at 3A max load.
*2. Add 0.1uF and 10uF capacitors across output terminal during ripple & noise test.
ENVIRONMENT
Operating Temp.
Storage Temp.
Operating Humidity
Storage Humidity
10
to 50
-20
to 70
20% to 90%, non-condensing
5% to 95%, non-condensing
PROTECTION
DC rail
Trigger Point/Range
Over Voltage Protection
Over Current Protection
Under Voltage Protection
Short Protection
All output to GND
+3.3V trip point
+5.0V trip point
+12.0V trip point
+3.3V
+5.0V
+12V1 & +12V2
+12V3 & +12V4
+3.3V trip point
+5.0V trip point
+12.0V trip point
8.5 Vmin
3.3 Vmin
2.0 Vmin
39A ~ 55A
22A ~ 35A
33A ~ 50A
33A ~ 50A
15.6 Vmax
4.5 Vmax
7.0 Vmax
Peak Power
1300W
16
17
297X 210 mm