Toughpower
CableManagement 1200W ATX12V 2.2 & EPS 12V 2.91 Version
Toughpower
CableManagement 1200W ATX12V 2.2 & EPS 12V 2.91 Version
8. Other Specification
8.1 Inrush Current:
55A max. when AC input 115Vac at 25
cold start.
110A max. when AC input 230Vac at 25
cold start.
8.2 Power Efficiency
80%(min.) at full load(typical) and 115Vac input.
8.3 CE Requirements
8.3.1 Conducted EMI
1. Meet FCC: ClassB
2. Meet CISPR 2 2: ClassB
3. Meet BSM I: ClassB
8.3.2 Safety Standards
1.Meet CUL (U L 6095 0 )
2.Meet TUV En60950
3.Meet CB (IE C 950)
4.Meet CE
8.3.3 Harmonic
Meet IEC1000-3- 2, Class D
9.Trouble Shooting
Condition 1:
No DC output. The fan or fans are motionless. Check:
1-1 Is the AC inlet plug firmly plugged into the PSU inlet
socket?
1-2 Is the wall socket, extension power cord, power strip
or surge protector in use, fully functional and wall
power switch turned
ON
?
1-3 Is the Main Board socket (20+4 pin) plug fully and
firmly inserted?
Condition 2:
The fan or fans began rotating and then stopped. The
system hangs without proceeding any further. Check:
2-1 Are the peripheral connectors firmly plugged into
accessory devices, such as the main hard drive, CD
ROM, etc?
2-2 If a plug has been inadvertently connected in an off-
set or reversed position, unplug the AC power source,
reconnect the offending connectors and then wait for
30 seconds before replug in the AC power source and
try again.
Note: If the power supply is still unable to power up after following the
above instruction, please send the unit back to your dealer or retailer
for after sales service.
18
19
297X 210 mm