INSTALLATION
3-6
Manual 0-2746
E. Using High Pressure Gas Cylinders
1. Refer to the following when using high pressure gas
cylinders as the gas supply:
CAUTION
Pressure should be set at 100 psi / 6.9 bar at the
high pressure gas cylinder regulator.
a.
Refer to the manufacturer’s specifications for in-
stallation and maintenance procedures for high
pressure gas regulators.
b. Examine the cylinder valves to be sure they are
clean and free of oil, grease or any foreign mate-
rial. Momentarily open each cylinder valve to blow
out any dust which may be present.
c.
The cylinder must be equipped with an adjustable
high - pressure regulator capable of outlet pres-
sures up to 100 psi / 6.9 bar maximum and flows
of up to 300 scfh / 141.5 lpm.
2. Use customer-supplied fittings to connect the gas line
to the power supply Regulator/Filter Assembly.
NOTE
For a secure seal, apply thread sealant to the fit-
ting threads, according to manufacturer's instruc-
tions. Do Not use Teflon tape as a thread sealer as
small particles of the tape may break off and block
the small gas passages in the torch. Connect the
gas supply as follows:
NOTE
Supply hose must be at least #4 hose / 1/4 in or 6
mm I.D.).
3.09 Connecting Torch Leads
CAUTION
This system is designed for use with the PCH / M
- 102 torch only. Do not connect any other torch to
this power supply.
The instructions for connecting the Torch Leads to the
Power Supply are different depending on the type of
leads. This sub - section covers connecting the Torch for
the following applications:
A. Hand Systems
B. Machine Systems (Unshielded Leads)
C. Machine Systems (Shielded Leads)
The Torch Leads must be properly installed to the Power
Supply for proper operation. If the torch leads were not
factory - installed, make all torch connections to the Torch
Bulkhead Panel for the desired application.
NOTE
Equipment ordered as a system will have the Torch
factory connected to the Power Supply.
Summary of Contents for PakMaster 75XL Plus
Page 2: ......
Page 6: ......
Page 12: ...GENERAL INFORMATION 1 6 May 14 2002...
Page 26: ...INSTALLATION 3 12 Manual 0 2746...
Page 45: ...Manual 0 2746 A 5 APPENDIX This page left blank...
Page 46: ...APPENDIX A 6 Manual 0 2746 A 02503 APPENDIX 5 SYSTEM SCHEMATIC...
Page 47: ...Manual 0 2746 A 7 APPENDIX A 02503...
Page 48: ......