INTRODUCTION
2-2
Manual 0-2746
7. Cut Capacity (Mild Steel)
3/4 inch / 19.1 mm ; 1 inch / 25.4 mm severance
8. Pilot Circuitry
Capacitive Discharge (CD), Pulsed DC
9. Weight
64 pounds / 29 kg with work lead
71 pounds / 32 kg with work lead and 25' Torch &
Lead
10. Overall Dimensions
19" / 482 mm High x 13" / 330 mm Wide x 24.8" /
630 mm Long
Overall dimensions are with Handle, Lead Wrap
Bracket, and Gas Regulator / Filter Assembly in-
stalled.
B. Gas Regulator / Filter Assembly
Specifications
The following specifications apply to the Gas Regulator
/ Filter Assembly only:
1. Gas regulator maximum gauge pressure
160 psi / 11 bar
2. Maximum input gas pressure
125 psi / 8.6 bar
3. Filter
Coalescent type filter
2.04 Power Supply Options and
Accessories
The following accessories are available for this power
supply. Refer to Section 6, Parts Lists, for catalog num-
bers and ordering information.
A. Single - Stage Air Line Filter
A Single Stage In - Line Air Filter for use with com-
pressed air shop systems. Filters moisture and par-
ticulate matter from the air stream to at least 0.85 mi-
crons.
B. Two Stage Air Line Filter
A Two Stage In - Line Air Filter for use on compressed
air shop systems. Filters moisture and particulate
matter from the air stream to at least 5.0 microns.
C. High Pressure Regulators
High pressure regulators are available for air and ni-
trogen. The regulators are used to set the proper pres-
sure for the type gas being used.
NOTE
Regulators should not be installed with options A
or B above.
D. Multi-Purpose Cart
Rugged steel cart on easy-rolling rear wheels and
front-mounted swivel casters. Provides maximum
mobility for the power supply and can also serve as
a display cart. Top shelf is 12 " / 305 mm x 20 / 508
mm. Steel handle is 30" / 762 mm high.
E. 575V Transformer
This step - down transformer allows the power sup-
ply to operate with 575 VAC three - phase input
power.
F. Computer Control Cable (CNC)
NOTE
This accessory can be used only with the PCM - 60
Torches.
The interface cable is available in two lengths, 25 ft /
7.6 m and 50 ft / 15.2 m . The cable is used to inter-
face the power supply with an auxiliary control de-
vice to provide OK - To - Move and ON / OFF sig-
nals.
Summary of Contents for PakMaster 75XL Plus
Page 2: ......
Page 6: ......
Page 12: ...GENERAL INFORMATION 1 6 May 14 2002...
Page 26: ...INSTALLATION 3 12 Manual 0 2746...
Page 45: ...Manual 0 2746 A 5 APPENDIX This page left blank...
Page 46: ...APPENDIX A 6 Manual 0 2746 A 02503 APPENDIX 5 SYSTEM SCHEMATIC...
Page 47: ...Manual 0 2746 A 7 APPENDIX A 02503...
Page 48: ......