Manual 0-2747
4-15
TROUBLESHOOTING
e.
Place the meter (+) lead on gate lead of Q6 and
meter (-) lead on source lead of Q6. The meter
should indicate approximately 2.5K ohms.
f.
Place the meter (+) lead on drain lead of Q6 and
meter (-) lead on source lead of Q6. The meter
should indicate >100K ohms.
4. FET Reset Diode Check
Use an ohmmeter set to the diode function and check
the reset diode as follows:
a.
Place the meter (+) lead on E14 and the meter (-)
lead on E25 of the FET/Heatsink Assembly Ca-
pacitor PC Board to check the reset diode. The
meter should indicate between 0.4 to 0.6 volts us-
ing the diode function.
b. Reverse the meter leads and the indication should
be a capacitor charging.
c.
Place the meter (-) lead on E14 and the meter (+)
lead on E26 of the FET/Heatsink Assembly Ca-
pacitor PC Board to check the reset diode. The
meter should indicate between 0.4 to 0.6 volts us-
ing the diode function.
d. Reverse the meter leads and the indication should
be a capacitor charging.
If the indication is a short, then replace the FET/
Heatsink Assemblies.
CAUTION
The FET / Heatsink Assemblies are matched and
balanced during production and must be replaced
in pairs.
5. FET Output Rectifier Check
Use a digital meter, diode or ohms function, to check
the forward and reverse bias of the output rectifiers
on the FET/Heatsink Assemblies as follows:
a.
Remove the wire from E16 and E18 on the Upper
and Lower FET/Heatsink Assemblies.
A-01215
E16
E18
E19
E17
E14
E15
b. Place the meter (+) lead on E16 and the meter (-)
lead on E18 of the FET/Heatsink Assembly to
check the output rectifier forward bias. The meter
should indicate between 0.3 to 0.6 volts using the
diode function or 100K ohms using the ohms func-
tion.
c.
Place the meter (+) lead on E18 and the meter (-)
lead on E16 of the FET/Heatsink Assembly to
check the output rectifier reverse bias. The meter
should indicate 'OL' using the diode function or
100K ohms using the ohms function.
d. Place the meter (+) lead on E17 and the meter (-)
lead on E19 of the FET/Heatsink Assembly to
check the output rectifier forward bias. The meter
should indicate between 0.3 to 0.6 volts using the
diode function or 100K ohms using the ohms func-
tion.
e.
Place the meter (+) lead on E19 and the meter (-)
lead on E17 of the FET/Heatsink Assembly to
check the output rectifier reverse bias. The meter
should indicate 'OL' using the diode function or
100K ohms using the ohms function.
Summary of Contents for Pak Master 75XL Plus
Page 2: ......
Page 6: ......
Page 16: ...INTRODUCTION 2 2 Manual 0 2747...
Page 49: ...Manual 0 2747 6 5 REPLACEMENT PARTS This page left blank...
Page 71: ...Manual 0 2747 A 15 APPENDIX Notes...
Page 72: ...APPENDIX A 16 Manual 0 2747 APPENDIX 12 SYSTEM SCHEMATIC A 02503...
Page 73: ...Manual 0 2747 A 17 APPENDIX A 02503...
Page 74: ......