Manual No. 0-4818 Auto-Cut 300
2
4-15
OPERATION
Status
Code
5-1
CANBUS Failure to
Acknowledge fault.
If GCM 1000, Basic ID signal missing; Other gas controls, Fiber
disconnected or broken, Transceiver (what fiber plugs into) fault, replace
Gas control PCB or CCM
CANBUS Off due to
excessive data errors;
CANBUS data error warning
.
Errors increasing, will soon
fault.
5-4
CCM Message not sent
Dirt on fiber ends or in connectors, blow out with clean dry air; fiber not
locked into connector; sharp bends in fiber; fiber defective; CANBUS
hardware error (CCM or Gas Control PCB)
6-1
CCM Analog Voltage Error
Replace CCM
6-2
CCM ADC or DAC error
Replace CCM
Torch coolant tube broken or missing;
CCM fault, replace CCM
6-4
CCM Data Memory error
Replace CCM
Status Code Key (cond)
Message
Cause/Remedy
5-2
Dirt on fiber ends or in connectors, blow out with clean dry air; fiber not
locked into connector; sharp bends in fiber; fiber defective;
5-3
Dirt on fiber ends or in connectors, blow out with clean dry air; fiber not
locked into connector; sharp bends in fiber; fiber defective;
6-3
Coolant Flow too High error
,
flow > 2.7 gal/min
Summary of Contents for AUTO-CUT 30 O2
Page 4: ...Thispageintentionallyblank...
Page 8: ...blank...
Page 24: ...Manual No 0 4818 Auto Cut 3002 2 8 SPECIFICATIONS This Page Intentionally Blank...
Page 68: ...Manual No 0 4818 Auto Cut 3002 3 44 INSTALLATION Intentionally Blank...
Page 86: ...Intentionally Blank...
Page 107: ...Manual No 0 4818 Auto Cut 3002 6 19 Parts List This page is blank intentionally...
Page 124: ...Manual 0 4818 Auto Cut 3002 A 8 APPENDIX This page intentionally blank...
Page 129: ...Manual 0 4818 Auto Cut 3002 A 13 APPENDIX This page intentionally blank...
Page 147: ...This Page Intentionally Blank...