Manual No. 0-4818 Auto-Cut 300
2
4-13
OPERATION
Status
Code
1-1
System not Enabled or Missing
AC Input Phase
Plasma Enable Off ; External E-Stop Activated or CCM
TB1-1&2 jumper missing; Missing AC Phase; No power
to GCM 2000 or 2010 Gas Control, check GCM control
cable connected, reset CP4 or CP5 circuit breaker in
power supply, blown fuse F19 in GCM.
Pilot did not start within 15 seconds.
Preflow pressure too high; Defective Arc Starter
1-3
Lost Pilot
Pilot went out without shutoff signal; Preflow pressure
too high; cut current set too low for consumables.
1-4
Loss of Transfer
Arc transfer (>50 ms.) then arc lost with START still on.
Standoff too high; Current set too low.
1-5
Of the Plate
Function not currently enabled.
1-6
Pilot Timed out w/o Transfer
Must transfer from Pilot to Cutting Arc in 85 ms. (SW8-1
OFF) or 3 sec. (SW8-1 ON). Standoff too high or void in
work under torch; cut current too low for consumables;
Preflow pressure too low.
1-7
Tip Saver
Function not currently enabled.
1-8
Possible Shorted Torch
Detected tip voltage too close to electrode voltage.
Plasma flow/pressure too low; Plasma leak; cut current
too high; shorted torch body; consumable parts worn out.
2-1
Missing Phase
Blown fuse, Broken or loose connection on power cable
Inverter(s) not configured correctly for input voltage;
Poor power quality (brownouts, dropouts);
Input power capacity / wiring too small causing voltage
drop; broken or loose power cable connections.
2-3
Inverter or Pilot Regulator Over
Temperature
Failed fan; Ambient above 40 deg C. (104 F); Blocked
airflow
2-4
Power Supply not Ready
PCB7, PCB4, poor connection, Defective inverter
2-5
DC Output Low
Output less than 60 VDC; Defective inverter, shorted
output; Shorted pilot regulator (chopper); CCM voltage
sense (J6) wire open or disconnected.
2-6
Primary over current or
imbalance fault
Over current or imbalance detected in inverter primary
circuit, remove power to reset; defective inverter; voltage
surge.
2-7
Unexpected current
Current >20A in work or pilot leads before pilot ignition;
Possible shorted torch; Defective current sensor.
2-8
Unexpected current in pilot
circuit
Current > 5A in pilot circuit; wrong or mismatched
consumables; Pilot lead shorted to negative in torch tube;
Possible shorted torch
2-9
Unexpected current in work
lead
Current > 5A in work lead; Short to chassis in RAS;
Negative lead short to gnd.
2-2
Wrong input voltage
Status Code Key
Message
Cause/Remedy
1-2
Pilot Ignition Failure
Summary of Contents for AUTO-CUT 30 O2
Page 4: ...Thispageintentionallyblank...
Page 8: ...blank...
Page 24: ...Manual No 0 4818 Auto Cut 3002 2 8 SPECIFICATIONS This Page Intentionally Blank...
Page 68: ...Manual No 0 4818 Auto Cut 3002 3 44 INSTALLATION Intentionally Blank...
Page 86: ...Intentionally Blank...
Page 107: ...Manual No 0 4818 Auto Cut 3002 6 19 Parts List This page is blank intentionally...
Page 124: ...Manual 0 4818 Auto Cut 3002 A 8 APPENDIX This page intentionally blank...
Page 129: ...Manual 0 4818 Auto Cut 3002 A 13 APPENDIX This page intentionally blank...
Page 147: ...This Page Intentionally Blank...