page 8
Settings DIP Switch
If the machine is to be programmed via the serial port, the DIP switches 1-3 has to be set to “ON“. In normal ope-
ration they has to be set to “OFF“.
If the pc-board is used in a 320SP, the DIP switch 4 has to be set to “ON“. For the use in a 400SP or 500SP, DIP
switch 4 has to be set to “OFF“.
DIP switch ON
OFF
1
mode serial programming
mode normal operation
2
mode serial programming
mode normal operation
3
mode serial programming
mode normal operation
4
con
fi
guration 320SP
con
fi
guration 400SP, 500SP
Measuring points
designation
measure point
result
solenoid valve
X10/1
X10/2
+
gnd
+24V DC
supply voltage
control transformer
X6/1
X6/3
~
~
230V AC
supply voltage
fan group 1
X7/1
X7/2
~
~
230V AC
supply voltage
fan group 2
X25/1
X25/2
~
~
230V AC
supply voltage
cooling pump
X13/1
X13/2
~
~
230V AC
output voltage
control transformer
X2/1
X2/2
~
~
18V AC
X2/3
X2/4
~
~
42V AC
supply voltage
fl
ow meter
X9/1
X9/3
+
gnd
+15V DC
supply voltage
CAN bus
X8/1
X8/2
gnd
+
+15V DC
X14/1
X14/2
gnd
+
+15V DC
X20/1
X20/2
gnd
+
+15V DC