Common Logic Functions
component
function cause
fan (power unit)
on
power modul temperature over 30°C
fan (power unit)
off
power modul temperature below 30°C
fan (cooling system)
on
after detection „welding current on“
fan (cooling system)
off
after welding process, two minutes post-cooling time
pump
on
after detection „welding current on“
pump
off
after welding process, two minutes post-cooling time
Gas test
press the buttons
-
(arrow up) and
“gas type“ (+) at the same time
the gas valve is activated for 30 sec.
-
a countdown is shown in the display
-
press button “gas type“ (+) again to end the test manually
-
Pump test
press the buttons
-
(arrow up) and
“material type“ (-) at the same time
the cooling pump is activated for one minute
-
a countdown is shown in the display
-
press button “material type“ (-) again to end the test manually
-
Reset adjustments
press the buttons
-
(arrow up) and
TT
Enter
“TT Enter“ at the same time
all secondary parameters are reset to their default values
-
if Tiptronic is active, the settings of the current job are reset to their programmed values
-
all adjustments of the Extras menu remain unchanged
-
Master reset
press the buttons
-
(arrow up) and
Mode
“Mode“ together for about
fi
ve sec.
the display shows “Master Reset“
-
the machine is reset completely to factory settings
-
!!! CAUTION : all Tiptronic jobs are deleted after a Master Reset !!!