Feature Description
Save/Load Function
•
A total numbe
r
of 5 p
r
og
r
ams can be saved into the
185AC/DC memo
r
y.
SAVE
the Current Weld Parameters into Memory
•
P
r
ess and HOLD the
SAVE
button. Beep will sound and
the Digital Mete
r
will show a numbe
r
1.
•
Select a memo
r
y location by
r
otating the cont
r
ol knob,
1 to 5 is displayed on the mete
r
.
•
Afte
r
selecting the desi
r
ed memo
r
y location (i.e. 1 to 5),
p
r
ess the
r
ight sc
r
oll button and the machine will give a
beep to confi
r
m the weld pa
r
amete
r
s f
r
om the cont
r
ol
panel a
r
e saved.
LOAD
(retrieve) a Program to Control Panel
•
P
r
ess and HOLD the
LOAD
button. Beep will sound and
the Digital Mete
r
display will show a numbe
r
1.
•
Select a memo
r
y location by
r
otating the cont
r
ol knob,
1 to 5 is displayed on the mete
r
.
Afte
r
selecting the desi
r
ed memo
r
y location (i.e. 1 to 5),
p
r
ess the
r
ight sc
r
oll button and the machine will give a
beep to confi
r
m the weld pa
r
amete
r
s a
r
e loaded onto the
cont
r
ol panel.
Table 4-6:Powe