Gas and Electric Supply Zones
NOTICE:
— If not already present, install gas shut-off valve in an
easily accessible location.
— Make sure all users know where and how to shut off
the gas supply to the range.
— Any opening in the wall behind the appliance and any
opening in the floor under the appliance must be
sealed.
The gas ranges may be connected to the power supply
with a range supply cord kit or by hard-wiring to the power
supply. It is the responsibility of the installer to provide the
proper wiring components (cord or conduit and wires) and
complete the gas connection as dictated by local codes
and ordinances, and/or the National Electric Code. The
units must be properly grounded.
Refer to “Step 6:
Electrical Requirements, Connection & Grounding” for
details.
Figure 4: Gas & Electrical Supply Locations for Dual Fuel Ranges
Range Width
30” or 36” (762 or 914 mm)
GAS & ELECTRICAL SUPPLY ZONE
A
B
C
D
Model
A
B
C
D
30” (762 mm)
5¾” (146 mm)
18
5
4⅜” (111 mm)
36” (913 mm)
8
19
8⅛” (206 mm)
4⅜” (111 mm)
1
/
16
”
7
/
16
” (468 mm)
13
/
16
”(148 mm)
13
/
16
”(503 mm)
(205 mm)
Gas & Electrical Supply Locations for 30” and 36” Dual Fuel Ranges
Range Width
48” (1219 mm)
GAS ZONE
ELECTRICAL
ZONE
3”
(76 mm)
(151 mm)
Gas & Electrical Supply Locations for 48” Dual Fuel Ranges
4⅜”
(111 mm)
4⅜”
(111 mm)
10¾”
(273 mm)
15
/
16
”
5
11
/
16
”
18
(475 mm)
2” (51 mm) max.
protrusion from wall
for gas or electrical
supply.
2” (51 mm) max.
protrusion from wall
for gas or electrical
supply.