Installation Instructions
English 10
Figure 4: Installation Clearances with Flush Island Trim
As defined in the “National Fuel Gas Code” (ANSI Z223.1, Current Edition).
Clearances from non-combustible materials are not part of the ANSI Z21.1
scope and are not certified by CSA. Clearances of less than 12" (305 mm)
must be approved by the local codes and/or by the local authority having jurisdiction.
Combustible
Materials
31¼" (794 mm)
29⅛" (740 mm)
36" (914 mm) min.
to combustible
materials
25⅛" (638 mm)
max. recess depth
Combustible
Back Wall
35⅞" (911 mm) Min.
36¾" (933 mm) Max.
26⅞" (683 mm)
48¾" (1238 mm)
Installation Clearances with Flush Island Trim
12” (305 mm) min. to
combustible surface
with Flush Island Trim
12” (305 mm) min. to
combustible surface
with Flush Island Trim
12" (305 mm) min. to
combustible surface
with Flush Island Trim
If an inner wall
is used under the
cantilever counter
top, there should be a
⅛" (3 mm) gap from
the rear of the range
to the inner wall.
For Flush Island Trim
For Flush Island Trim
For Flush Island Trim
installations, counter
installations, counter
installations, counter
surface should have
surface should have
surface should have
a cantilever edge
a cantilever edge
a cantilever edge
meeting the back
meeting the back
meeting the back
section of the Flush
section of the Flush
section of the Flush
Island Trim accessory.
Island Trim accessory.
Island Trim accessory.
Shaded area behind
range indicates
minimum clearance
to combustible surfaces,
combustible materials
cannot be located within
this area.
Shaded area behind
range indicates
minimum clearance
to combustible surfaces,
combustible materials
cannot be located within
this area.
Shaded area behind
range indicates
minimum clearance
to combustible surfaces,
combustible materials
cannot be located within
this area.