10. Remove the white plastic side connector from the potentiometer
by pressing on the connector’s tab. (see Figure 85).
11. Detach the XLO valve from the potentiometer by using a small
flat-blade screwdriver to remove the XLO valve from the
potentiometer standoffs. Then slide the potentiometer off the valve
stem (see Figure 86).
12. Replace the potentiometer if needed.
Gas Leaks
With electrical power off, carefully check for gas leaks at each gas
component that was removed, replaced, or otherwise serviced using a
gas leak detector or bubble test. If potentiometer was accessed by
removing an XLO valve, you may need the electrical power to be on
when testing for gas leaks.
Use extreme caution
when performing
gas leak testing on XLO valves with the electrical power on.
4.5.8 Manifold Removal and Replacement
Figure 88: Typical Manifold
Although range components can usually be accessed and replaced
without removing the manifold, this procedure is provided if the
manifold for the maintop burners needs to be replaced, for example, if
damage is sustained due to a gas leak in the manifold, or if the
threading on the manifold is bad after removing the regulator.
NOTE:
The manifold is sold as an assembly, which comes with XLO
and standard valves pre-installed.
Be sure to check QuickFinder for relevant information, documentation,
and the correct part number when replacing this component.
1. Follow all safety precautions and steps in
page
2. Follow all steps in
Accessing Components under the Maintop
3. Remove burner support rails (with jet holder assemblies attached)
by following the steps in
Removing the Burner Support Rail,
4. Remove the regulator from the manifold
(see Regulator Removal
page
5. Remove all knobs from their valve stems by slowly pulling knobs
straight out, away from control panel.
6. At each of the locations shown in Figure 123 on page 65, remove
and retain two screws inside each bezel (see Figure 89) to detach
the manifold support brackets at the back of the control panel (see
Figure 90 on page 49).
Figure 89: Screws that Attach to Manifold Support Bracket
1