Installation Instructions English | 16 |
Wire Routing
Vertical Discharge Wire Routing
Horizontal Discharge Wire Routing
Blower Motor Installation
All hoods require the choice of a Remote, Inline, or Integral
Blower. Use only THERMADOR
®
blowers with
THERMADOR ventilation hoods. All blower models are
sold separately. See the
Ventilation Planning Guide
for
recommended blowers. Contact Customer Service for
additional options.
The hood is rated for 120 VAC, using a 20 amp circuit
breaker.
Blower selection will vary based on the volume of air that
needs to be moved and the length and location of the duct
run. For long duct runs with multiple turns and bends,
consider using a more powerful blower. For the most
efficient air-
À
ow exhaust, use a straight run or as few
elbows as possible (refer to
“Ductwork Preparation” on
page 8
).
Figure 21: Vertical Discharge
Figure 22: Horizontal Discharge
Route wires here
Route wires here
Route wires here
Blower
SKU
Voltage Current Circuit Breaker
Remote VTR1330
a
120
8.8
20 amp
Inline
VTI1010
a
120
5.7
20 amp
Integral VTN1090
a
120
5.4
20 amp
a
Indicates a letter designating the release year.
Table 3: Blower & Circuit Breaker Ratings
WARNING
Cutting the plug of the blower will void the warranty or
eligibility for return or exchange.
CAUTION
To reduce the risk of fire and electric shock, install this
range hood only with the blowers listed in the
Ventilation
Planning Guide
.