Installation Instructions English | 11 |
1. To change to horizontal discharge, move the discharge
cover, shown in
Figure 5
, to the top of the hood. The
plate is held in place by (4) 3/8'' hex nuts.
Assembly of the Transition
The supplied transition mounts to the top or rear of the
hood, depending on the discharge direction.
A minimum height clearance of 7½'' (190 mm) is needed
above the hood for transition mounting. See
“Before You
Begin” on page 5
for overall hood dimensions.
2. Depending on direction of discharge, align mounting
holes at base of transition with the mounting holes of
the ½'' (13 mm) flange located at the top or rear of the
hood.
3. Fasten transition to hood using four (4) 1/4'' (6 mm)
sheet metal screws included with hood (
Figure 7
).
4. Seal connection between transition and hood with
aluminum tape.
DO NOT
use duct tape. Ensure that
the connection is completely sealed (
Figure 7
).
5. Remove tape holding damper closed.
Figure 5: Discharge Direction
Figure 6: Transition Dimensions
7½"
(190)
7½"
(190)
7½"
(190)
25½"
(647)
25½"
(647)
25½"
(647)
18"
(457)
18"
(457)
18"
(457)
inches (mm)
Figure 7: Transition Connection