background image

HWS

Shut-off

  valve

Hot water supply line

(520 mm)

20 1/2"

WARNING

ELECTRICAL SHOCK HAZARD

DISCONNECT ELECTRICAL POWER AT
THE CIRCUIT BREAKER BOX OR FUSE
BOX BEFORE INSTALLING THE
DISHWASHER.

ELECTRICALLY GROUND DISHWASHER.

USE COPPER CONDUCTORS ONLY.
FAILURE TO  FOLLOW THESE
INSTRUCTIONS COULD RESULT IN
SERIOUS INJURY OR DEATH.

23-

5

/

8

" - 24"

(600 - 610 mm)

2-

3

/

8

"

(60 mm)

3-

1

/

2

"

(90 mm)

AVERTISSEMENT

RISQUE DE CHOC ÉLECTRIQUE

AVANT D’INSTALLER LE LAVE-VAISSELLE,
COUPER LE COURANT ÉLECTRIQUE AU
DISJONCTEUR OU À LA BOÎTE DE
FUSIBLES

EFFECTUER LA MISE À LA TERRE

UTILISER UNIQUEMENT DES
CONDUCTEURS EN CUIVRE.
SI L’ON N’OBSERVE PAS CES INSTRUCT–
IONS, IL PEUT EN RÉSULTER DE GRAVES

The electrical supply must be 120 volt, 60 Hz, 12 ampere,
properly grounded, positioned as shown in Figure 7, and
should be installed by a qualified electrician. No other
appliances or outlets should be on this circuit.

Cut a 1” (25.4 mm) diameter hole in the cabinet for the
electrical wiring to pass through. If this hole is cut in a
wood cabinet, the hole should be sanded until smooth.

Electrical Supply

Figure 7.

Access holes for electrical cord, drain line and water
line must be rounded and smooth. Holes must not be
larger than 1-1⁄2” diameter.

Hot Water  Supply

The hot water line to the dishwasher must provide
between 5 - 120 psi (0.3 - 8.27 bars) water pressure.

The hot water heater should be set to deliver 140

°

F

(60

°

C) water temperature to the dishwasher.

A 3/8” minimum O.D. copper tubing inlet line is
recommended.

All solder connections must be made before water
line is connected to the dishwasher’s inlet water
valve. Do not solder within 6 inches (152.4 mm) of
the dishwasher’s inlet water valve

.

After determining where the water supply line will enter
the dishwasher, drill a 1” (25.4 mm) diameter access
hole and run the line to the approximate fill valve
location, as shown in Figure 7.  It is recommended that
a shut-off valve (not supplied) be installed in the hot
water supply line in a readily accessible location.

Drain Hose

The dishwasher comes with a seven (7) foot drain hose.
An access hole must be made to allow the drain hose
to be run to the drain connection location.

Figure 6.

Preparing the Location

Openings for electrical, water and drain lines must be
installed in the marked area as shown in Figures 6 and 7
to avoid interference with the dishwasher frame or other
components.

3

Summary of Contents for DW1246UB

Page 1: ...Local Electrical Inspector s use INSTALLER Please leave these Installation Instructions with this unit for the owner OWNER Please retain these instructions for future reference WARNING Disconnect powe...

Page 2: ...t Water Supply 3 Drain Hose 3 Electrical Supply 3 Inspecting The Dishwasher 4 Placing The Dishwasher 4 Drain Hose 5 6 Connecting Hot Water Supply 6 Connecting Electrical Supply 7 Grounding Instruction...

Page 3: ...t blade screwdriver C Phillips screwdriver D Torx screwdriver 20 E Electric Drill F Hole saw or 1 hole cutter G Hammer H Level I Open end wrench J Adjustable wrench 2 required K Pipe wrench 2 reqd L W...

Page 4: ...If the valve or water line freezes flooding may occur Such ruptures are not covered by the warranty If the dishwasher is to be installed in a corner make sure there is adequate clearance to open the d...

Page 5: ...ss holes for electrical cord drain line and water line must be rounded and smooth Holes must not be larger than 1 1 2 diameter HotWater Supply The hot water line to the dishwasher must provide between...

Page 6: ...ounter top that could be damaged by drilling Once decided set the mount ing brackets before sliding the dishwasher into place see Figure 10 Once slid into place make final leveling adjustments as show...

Page 7: ...gap The rubber drain hose must be resistant to heat and detergent The drain hose may be obtained from a plumbing hardware or automotive supply outlet The rear leveling leg is adjusted by turning the...

Page 8: ...s which might restrict water flow AVERTISSEMENT Si l on ne respecte pas la hauteur appropri e pour le branchement du tuyau de vidange 20 po 500 mm au dessus du niveau du sol avec une grande boucle ou...

Page 9: ...e pulled down to the maximum position the total control panel height would be 6 1 8 156 mm The purpose of this extension piece is to allow you to match the control panel height to the horizontal line...

Page 10: ...ate Then proceed with Pictogram 3 Pictogram 3 on template If you will be using the extension piece to match the horizontal drawer line place door template on door of dishwasher being sure that correct...

Page 11: ...Figure 20 Final check list CHECK ELECTRICAL REQUIREMENTS BE SURE YOU HAVE CORRECT ELECTRICAL SUPPLY AND RECOMMEDNED GROUNDING METHOD Turn on the hot water shut off valve and electrical supply Inlet w...

Page 12: ...ithout notice Some models are certified for use in Canada Thermador is not responsible for products which are transported from the U S for use in Canada Check with your local Canadian distributor or d...

Reviews: