background image

©2018 Thermaco, Inc. All rights reserved  •  Patented/Patents Pending  •  Specifications subject to change without notice

Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • (336) 629-4651

MNL-TZ-1826  19

A THERMACO® Technology

Trapzilla

®

 Grease Interceptor

Installation and Operations Manual

TZ-1826 Models

AEF

MNL-TZ-1826  18

5.5 Trimming and Setting the ECA-TZ-18 Single-Piece Extension Collar

In-Ground Trapzilla Models ship with a built-in, 

single-piece, 18” extension collar that must be 

trimmed and then set to the correct height to 

bring the Solid Top Cover to grade.

Follow the steps below to set the extension 

collar prior to backfilling the hole with 

concrete.

Amount of extension collar needed to bring 

Solid Top Cover to grade.

Step 2:  Remove the extension collar adapter ring from the 

unit with the extension collar still in place.  On the underside 

of the cover, mark the excess extension collar length at the 

bottom of the four (4) “skirt” portions of the adapter ring.  

Check the extension collar height dimension frequently 

during this marking to ensure that the collar has not moved.  

Extend this mark between the gaps in the “skirt” so that the 

collar is marked all around.

Step 1:  With the Trapzilla unit installed in its permanent 

location,  raise  the  telescoping  extension  collar  to  finished 

grade or floor level.  Measure the height from the top of the 

unit to this finished extension collar height and record this 

dimension.

Note: If the floor will have a tile covering, allow for the tile 
thickness when determining the extension collar height.  

8.25"

Extension collar

Skirt

Mark excess extension collar length

at the four (4) "skirt" portions of

the adapter ring.

8.25

Step 5:  Working from the bottom of the assembly, install 

eight (8) self-drilling, self-tapping screws (provided) through 

the extension collar wall and into the adapter ring.  Two of 

these screws should be installed in each of the four (4) skirt 

areas of the adapter ring. Check the extension collar height 

dimension frequently during this operation to ensure that the 

collar has not moved.  Note:  Use caution when tightening 

these screws to ensure that they do not strip.

Step 6:  Place the adapter ring/extension collar assembly 

onto the Trapzilla unit.  Position the small cover onto the 

extension collar.  Secure the adapter ring and the small 

cover with the brass nuts and flat washers provided. Seal 

the gap between the 18” extension collar and extension 

collar adapter ring using a silicone sealant.

Step 3:  Remove the extension collar from the adapter ring 

and, with an appropriate saw, cut along the line created in 

Step 2 to remove the excessive extension collar.

Step 4:  Reinsert the extension collar into the adapter ring 

ensuring that the cover alignment key on the extension 

collar is aligned with its recess in the adapter ring. 

 

 

Reset the extension collar height to the dimension 

determined in Step 1.

Line marking the bottom

 

of the "skirt" (adapter 

ring has

 

been removed

 

for clarity)

Excess part of 

extension collar 

to be discarded 

after cutting 

along line

Reinsert extension collar into adapter

ring to insure alignment.

Adapter ring

Extension collar

Modified extension collar

Self-tapping screws

8 Places

Adapter ring

"Skirt"

5/16-inch Hex Nut

4 Places

5/16-inch Washer

4 Places

Note:  Tighten down the flat

washers and brass nuts using

a 5/16-inch socket and rachet.

 

Do not over tighten.

Note: Drawing for reference only.  Equipment must be installed in compliance with all applicable laws, regulations 

and codes, including plumbing codes.  Installation should be performed by a qualified plumber. 

IMPORTANT: Excess extension collar must be trimmed on all units.  Do not allow 
additional extension collar to extend beyond bottom of adapter ring.  On units 
where extension collar is completely recessed, the extension collar should still 
be secured and the excess extension removed as in step 3. 

Summary of Contents for Trapzilla TZ-1826

Page 1: ...HOLE OR PART WITHOUT WRITTEN CONSENT FROM THERMACO INC POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREE...

Page 2: ...There are many factors influencing odor evolution and dissemination These include room ventilation kitchen menu ambient temperatures ware washing practices grease oil input daily input fluid volume sa...

Page 3: ...andard STC 22 cover Each TZ 1826 would require two 2 FTCA 22 covers SSA 1826 Support Stand for TZ 1826 forAbove Ground Installations Must be fully supported not to be installed over grates Included wi...

Page 4: ...diameter of the system s outlet connection must be present as close as possible to the Trapzilla outlet to prevent possible siphonage problems The Vent on the Outlet piping is to be installed in accor...

Page 5: ...ut before and after all Trapzilla Installations Outlet Inlet Cleanout Cleanout Outlet Vent Connect to facility vent Note Drawing for reference only Equipment must be installed in compliance with all a...

Page 6: ...ts Connect to facility vent Low Head Flow Control not pictured to be installed as close as possible to inlet of first grease interceptor Cleanout Note Drawing for reference only Equipment must be inst...

Page 7: ...ESS NOTED 646 GREENSBORO STREET PO BOX 2548 ASHEBORO NC 27203 VOICE 336 629 4651 FAX 336 626 5739 Decimals XX 03 XXX 015 Unless otherwise specified Dimensions are in inches Tolerances Angular 1 CHECKE...

Page 8: ...it may also be installed in the ground inside or outside of the facility For instances where the facility drainage piping requires an extension collar that is more than the 18 provided by the built in...

Page 9: ...s purchased separately In some cases TZ 1826 may be installed in locations where built in extension collar will not reach grade In these cases the two piece ECA TZ 29 Extension Collar purchased separa...

Page 10: ...dapter ring Two of these screws should be installed in each of the four 4 skirt areas of the adapter ring Check the extension collar height dimension frequently during this operation to ensure that th...

Page 11: ...bolts and fully remove the 22 lid to pump out It is not necessary to remove adapter lid to pump out Trapzilla 2 Begin by taking the grease from the top of the main chamber until all grease is removed...

Page 12: ...not arising out of defects in workmanship or materials Thermaco shall not be responsible for damage to Products resulting from ultraviolet light exposure vault flooding sewer line back up pumping or...

Reviews: