                      Vent-Free Gas Wall Heater     

MODEL:

 

WDFT060/100/250-VF-IR (DUAL FUEL) 

                                             

WNT060/100/250-VF-IR (NATURAL GAS)   

         

 

WLT060/100/250-VF-IR (PROPANE GAS)

    

                                                                                                                                                                       

     

 

               

  CAUTION - FOR YOUR SAFETY 

         

 

   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

                                                                                                                                                                                   

Reecon North America 

  1090 

Freeport 

Road 

2

nd

 Floor 

                     Pittsburgh, PA 15238 

                                                                                    Conforms to ANS Z21.11-2-2013. Gas-Fired Room Heater Volume II, Unvented Room Heater 

This is an unvented gas-fired heater. It uses air (oxygen) from the room in 
which it is installed. Provisions for adequate combustion and ventilation 
air must be provided. Refer to 

Air For Combustion and Ventilation 

section 

on page 8 of this manual. 

Warranty is void if not professionally

 

installed.

 

INSTALLER: Leave this manual with the appliance 
CONSUMER: Retain this manual for future reference

 

This appliance may be installed in an aftermarket, permanently located, 
manufactured (mobile) home, where not prohibited by local codes. 
This appliance is only for use with propane or natural gas. 
This appliance is equipped with a simple means to switch between 
propane and natural gas in dual fuel models only. Field conversion by 
any other means including the use of a kit is not permitted. 

WARNING: 

This appliance is equipped for 

(Natural and/or Propane) gas. Field 
conversion is not permitted other than 
between natural or propane gases in dual 
fuel models only.            

 

Summary of Contents for WDFT060-VF-IR

Page 1: ...on on page 8 of this manual Warranty is void if not professionally installed INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference This appliance may be insta...

Page 2: ...propane gas Manifold Pressure W C 6 6 6 Nominal Input Pressure W C 11 11 11 Ignition Electric Pulse Electric Pulse Electric Pulse Package Dimension inches H W D 15 7 7 5 25 6 18 1 7 5 28 7 30 25 11 00...

Page 3: ...r having an input rating of more than 6000 Btu hr 1 758 W shall not be installed in a bathroom Model WLT060 VF IR WLT100 VF IR WLT250 VF IR Input Rating Btu hr 6000 10000 25000 Gas type LP LP LP Manif...

Page 4: ...dded to the gas can fade Gas may be present even though no odor exists WARNING Any change to this heater or its controls can be dangerous WARNING Do not use any accessories not approved for use with t...

Page 5: ...r and free of debris This will ensure enough air for proper combustion 6 If heater shuts off do not relight until you have provided fresh air from outside If heater keeps shutting off have it serviced...

Page 6: ...ugh fresh air PULSE IGNITION SYSTEM This heater is equipped with a battery powered electric pulse igniting system No AC power supply required Battery should be periodically checked and replaced accord...

Page 7: ...on 2 Remove all protective packaging applied to heater for shipping 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater 4 Remove thread protectiv...

Page 8: ...ot be installed in a room or space unless the required volume of indoor combustion air is provided by the method described in the NATIONAL FUEL GAS CODE ANSI Z223 1 NFPA 54 the INTERNATIONAL FUEL GAS...

Page 9: ...h Air Flow For Heater Location 6 DETERMINING FRESH AIR FLOW FOR HEATER LOCATION Using this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will i...

Page 10: ...be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction provide adequate combustion and ventilation air by one of the methods described in...

Page 11: ...hile using heater This will help circulate the heat throughout the house In the event of a power outage you can use this heater as your primary heat source Caution If you install the heater in a home...

Page 12: ...unting the attached bracket with folding anchor on desired location 2 Hang the heater on the bracket 8 CONNECTING TO GAS SUPPLY WARNING A qualified service technician must connect heater to gas supply...

Page 13: ...down protects it from freezing rain or sleet If flexible gas hose is applied it should meet the requirements of ANSI UL569 Standard for Pigtail and Flexible Hose Connection for LP Gas Improper regula...

Page 14: ...once 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve 2 Pressuriz...

Page 15: ...stem and any gas control which has been under water WHAT TO DO IF YOU SMELL GAS Open the window or door immediately Do not try to light any appliance Do not touch any electric switch do not use any ph...

Page 16: ...has heated up enough 4 Release both buttons If pilot goes out repeat step 3 and step 4 5 When the pilot flame stays stable slightly push the gas valve button down and turn from the PILOT position to t...

Page 17: ...o the position as your desired temperature approximately 50 O F to 100 O F from the position 1 to 5 To stop the heater shut off the valve in gas inlet line not included in delivery scope first then tu...

Page 18: ...ompressed air in a can You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could da...

Page 19: ...ned off or equipment shutoff valve is closed 2 Control knob not fully pressed in while pressing igniter button 3 Air in gas lines when installed 4 ODS pilot is clogged 5 Control knob not in PILOT posi...

Page 20: ...king ticking noise just after burner is lit or shut off 1 Metal is expanding while heating or contracting while cooling 1 This is common with most heaters If noise is excessive contact qualified servi...

Page 21: ...21 ILLUSTRATED PARTS Models WDFT060 VF IR...

Page 22: ...ter micro switch 31 Thermostat seat 10 Left insulation board 32 Right insulation board 11 Gas distribution valve bracket 33 Gas pipe nut 12 Gas distribution valve seat 34 Gas valve seat 13 Igniter kno...

Page 23: ...23 ILLUSTRATED PARTS Model WDFT100 VF IR...

Page 24: ...tion valve assembly 31 Pulse igniter 10 Rear insulation board 32 Battery pack 11 Igniter micro switch 33 Right insulation board 12 Gas distribution valve bracket 34 Gas pipe nut 13 Left insulation boa...

Page 25: ...25 ILLUSTRATED PARTS Model WDFT250 VF IR...

Page 26: ...s control valve 9 Bottom cover 29 Connecter 10 Rear cover 30 T connecter 11 Installation bracket 31 Igniter knob 12 Fixing racket 32 Gas distribution valve seat 13 Burning chamber 33 Gas distribution...

Page 27: ...27 ILLUSTRATED PARTS Models WNT060 VF IR WLT060 VF IR...

Page 28: ...valve assembly 27 NG ODS 9 Igniter micro switch 28 Knob 10 Left insulation board 29 Gas allocator 11 Gas distribution valve bracket 30 Right insulation board 12 Gas distribution valve seat 31 Gas pipe...

Page 29: ...29 ILLUSTRATED PARTS Models WNT100 VF IR WLT100 VF IR...

Page 30: ...G ODS 9 Gas distribution valve assembly 29 Pulse igniter 10 Rear insulation board 30 Battery pack 11 Igniter micro switch 31 Right insulation board 12 Gas distribution valve bracket 32 Gas pipe nut 13...

Page 31: ...31 ILLUSTRATED PARTS Models WNT250 VF IR WLT250 VF IR...

Page 32: ...tery pack 26 Connecter 9 Bottom cover 27 T connecter 10 Rear cover 28 Igniter knob 11 Installation bracket 29 Gas distribution valve seat 12 Fixing racket 30 Gas distribution valve bracket 13 Burning...

Page 33: ...lease send in the form below to our office listed below or register online at www thermablaster com Reecon North America Attn Thermablaster 1090 Freeport Road 2nd Floor Pittsburgh PA 15238 Contact Inf...

Reviews: