- 16 -
Heater Models:
WDFT060/100-VF-IR
WNT060/100-VF-IR
WLT060/100-VF-IR
Figure - 9
1. Turn the thermostat Control button to full position, turn the appliance gas valve (
-PILOT-OFF)
button to the “Pilot” position.
2. Push down the appliance gas valve and keep it depressed for several minutes, so that all the air in the
manifests are cleared out.
3. Keep the gas valve button depressed while pushing down the igniter button thoroughly until ignition
can be heard. Both buttons must be remain depressed for at least 15 seconds until the pilot is lit up
and the sensor has heated up enough.
4. Release both buttons. If pilot goes out, repeat step 3 and step 4.
5. When the pilot flame stays stable, slightly push the gas valve button down and turn from the PILOT
position to the on position (
)
QUICKLY without stopping in between positions. Heater will then
operate normally. Now you can turn the thermostat control button to the position as your desired
temperature (approximately 40
O
F to 80
O
F from the range min. to max.)
To stop the heater shut off the valve in gas inlet line (not included in delivery scope) first, then turn the
appliance gas valve to “OFF” position.
Heater Models: WDFT250-VF-IR
WNT250-VF-IR
WLT250-VF-IR
Figure - 10
Igniter button
Gas valve button
Temperature control button
Igniter button
Combination
control button
Summary of Contents for WDFT060-VF-IR
Page 21: ...21 ILLUSTRATED PARTS Models WDFT060 VF IR...
Page 23: ...23 ILLUSTRATED PARTS Model WDFT100 VF IR...
Page 25: ...25 ILLUSTRATED PARTS Model WDFT250 VF IR...
Page 27: ...27 ILLUSTRATED PARTS Models WNT060 VF IR WLT060 VF IR...
Page 29: ...29 ILLUSTRATED PARTS Models WNT100 VF IR WLT100 VF IR...