6. Maintenance 

6.1 Standard Air Filter 

The Ultra-Aire XT is equipped with a pleated cloth air filter. This 
filter should be checked every six months. Operating the unit with 
a dirty filter will reduce dehumidifier capacity and efficiency and 
may cause the compressor to cycle off and on unnecessarily on the 
defrost control. 

To access the air filter, remove the filter access panel from the end 
of the Ultra-Aire XT. The filter should be readily visible and can be 
removed by pulling them straight out of the Ultra-Aire XT. 

The pleated cloth filter can generally be vacuumed clean several 
times before needing replacement. DO NOT operate the unit 
without the standard filter or with a less effective filter than the 
standard filter. The heat exchange coils inside the unit could 
become clogged and require disassembly to clean. Filter non-
compliance invalidates the product warranty. 

6.2 High Efficiency Air Filter – MERV 14

An optional high efficiency pleated microglass paper filter is 
available for the Ultra-Aire XT. This filter is rated as 90%-95% 
efficient by the ASHRAE Dust Spot test method 52-76. The 
high efficiency pleated microglass paper filter should be used 
in conjunction with the standard filter. 

The filter housing is a 

seperate accessory

 that must be used with the MERV 14 filter.  

An additional MERV 11 pre-filter is sold with the filter housing.

This filter is able to remove allergy causing particles from the 
airstream. The high efficiency filter has a much larger surface area 
than the standard filter, thus the standard filter may need to be 
cleaned or replaced several times before the high efficiency filter 
requires replacement. Be careful not to damage the fabric media 
when handling the high efficiency pleated paper filter. Do not 
attempt to clean the high efficiency pleated paper filter. It should be 
replaced when it becomes restrictive.

6.3 Impeller Fan Oiling 

The impeller fan motor is factory lubricated for many years of 
normal operation, and no further oiling is required. 

6.4 Optional Fresh Air Return 

Check and clean the screen on the outdoor fresh air return 
seasonally. The screen may become plugged during the seasons 
when there are many particles in the outdoor air. 

7. Service 

7.1 Warranty 

A warranty certificate has been enclosed with this unit; read it 
before any repair is initiated. 

If a warranty repair is required, 

call the factory first at 1-800-533-7533 Ext. 8459 for warranty 
claim authorization and technical assistance.

7.2 Technical Description 

The Ultra-Aire XT uses a refrigeration system similar to an air 
conditioner's to remove heat and moisture from incoming air, and 
add heat to the air that is discharged (See Figure 15). 

Hot, high-pressure refrigerant gas is routed from the compressor 
to the condenser coil (See Figure 3). The refrigerant is cooled 
and condensed by giving up its heat to the air that is about to be 
discharged from the unit. The refrigerant liquid then passes through 
a filter/drier and capillary tubing which causes the refrigerant 
pressure and temperature to drop. It next enters the evaporator 
coil where it absorbs heat from the incoming air and evaporates. 
The evaporator operates in a flooded condition, which means that 
all the evaporator tubes contain liquid refrigerant during normal 
operation. A flooded evaporator should maintain nearly constant 
pressure and temperature across the entire coil, from inlet to outlet. 

The mixture of gas and liquid refrigerant enter the accumulator 
after leaving the evaporator coil. The accumulator prevents any 
liquid refrigerant from reaching the compressor. The compressor 
evacuates the cool refrigerant gas from the accumulator and 
compresses it to a high pressure and temperature to repeat  
the process. 

7.3 Troubleshooting 

Neither fan nor compressor running. Dehumidification is being 
called for. No fan call.

1. Unit unplugged or no power to outlet.
2. Humidity control set too high.
3. Loose connection in internal or control wiring.
4. Defective Compressor relay.
5. Defective control transformer.

Figure 15: 

Refrigeration System of Ultra-Aire XT 

11

Ultra-Aire XT105H, XT155H, and XT205H Installer’s & Owner’s Manual

Summary of Contents for Ultra Aire XT105H

Page 1: ...outdoor air may be ducted to the unit via a six inch round duct This provides fresh air to dilute pollutants and replenish oxygen content in the building The amount of fresh air ventilation can be reg...

Page 2: ...2 Ultra Aire XT105H XT155H and XT205H Installer s Owner s Manual...

Page 3: ...3 Ultra Aire XT105H XT155H and XT205H Installer s Owner s Manual...

Page 4: ...are Foot Typical Minimum Performance 80 F and 60 RH Water Removal Efficiency 105 Pints Day 8 8 Pints kWh 155 Pints Day 7 3 Pints kWh 205 Pints Day 5 7 Pints kWh Duct Connections Inlet 10 Round Duct Co...

Page 5: ...FOR HVAC INSTALLER ONLY 5 Ultra Aire XT105H XT155H and XT205H Installer s Owner s Manual...

Page 6: ...6 Ultra Aire XT105H XT155H and XT205H Installer s Owner s Manual...

Page 7: ...Ultra Aire Dehumidifier 7 Ultra Aire XT105H XT155H and XT205H Installer s Owner s Manual...

Page 8: ...T155H and XT205H Installer s Owner s Manual P N 4028539 with remote P N 4028407 Ultra Aire Dehumidifier RED YELLOW BLUE GREEN or BROWN WHITE Internal Connections OPTIONAL DAMPER 24 VAC DMP COMP FAN Ul...

Page 9: ...y the transformer Dehumidifier on Connect yellow and blue wires Fan only on Connect yellow and green or brown wires Accessory power 24volt AC power supply available for HVAC accessories between yellow...

Page 10: ...10 Ultra Aire XT105H XT155H and XT205H Installer s Owner s Manual DEH 3000 DEH 3000R DEH 3000 DEH 3000R Part No 4028539 Part No 4028407...

Page 11: ...peration and no further oiling is required 6 4 Optional Fresh Air Return Check and clean the screen on the outdoor fresh air return seasonally The screen may become plugged during the seasons when the...

Page 12: ...ls from the main unit together only the impeller fan should run Disconnect the wires 3 Connect the yellow and blue pigtails from the main unit together the compressor and impeller fan should run 4 If...

Page 13: ...a very corrosive acid and water These contaminants must be carefully removed otherwise even small residues will attack replacement compressor motors and cause failures The following procedure is effe...

Page 14: ...ction tube between the accumulator and the compressor It will automatically shut the compressor off if the low side refrigerant temperature drops due to excessive frost formation on the evaporator coi...

Page 15: ...ONTROL WIRING Electric Schematics of the Ultra Aire XT N O WHT 4 UNIT E BOX 1 59 1413 WHT 4 BLK 1 8 2 3 2 2 2 3 7 5 COM COM 115V 24V WHT 6 BLU 7 YEL 6 RED 1 GRN 5 RED 6 5 WHT 6 BLU 2 BLU 2 BLK 1 BRN 3...

Page 16: ...029714 1 XT155 Compressor Overload NOT SHOWN 4031574 1 XT205 Compressor Overload LOCATED IN COMPRESSOR CAP Item Part No Qty Description 8 4032196 1 XT105 Impeller 8 4026657 1 XT155 Impeller 8 4031089...

Page 17: ...Condensate Pump Kit External 4023672 1 Duct Damper 6 Diameter Electrically Actuated 4025560 1 Switch Black SPDT On Off 4024369 1 Merv 11 Standard Filter 20 x 16 x 2 4032221 1 Filter Box Needed when M...

Page 18: ...is shut release the door latch Collar Install Remove the 2 round ducts oval duct seal and small bag of mounting hardware from inside the rectangle opening Adhere seal onto the back of oval duct and mo...

Page 19: ...ts related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Responsibilit...

Page 20: ......

Reviews: