You can select from:

“MON-FRI” “SAT-SUN”

 for separate weekday and weekend 

schedules, or 

“MON-SUN”

 which gives you equal weekday and 

weekend schedules.

3. Using the Up/Down 

“RH” 

buttons, highlight and then select 

one of the two choices. The example given shows how to 
program separate weekday and weekend schedules. The same 
method is used if you choose the other program.

Example: menu when you select 

“MON-FRI” “SAT-SUN”

:

1.  Enter the starting time for weekdays using the up/down 

“RH” 

buttons to change the time.

2.  Press the 

“PROGRAM ENTER” 

 button to switch to the 

“OPEN FOR”

 setting. Using the up/down 

“RH”

 buttons, 

change the duration that the damper will ventilate fresh air.

3.  Press the 

“PROGRAM ENTER”

 button to switch to the

 

“CLOSED FOR” 

setting. Using the up/down 

“RH” 

buttons, 

change the duration that the damper will remain closed 
between ventilation cycles.

For the example given, starting at 8:00AM in the morning, the 
control will ventilate fresh air for 15 minutes then stop for 15 
minutes. This schedule of 15 minutes open, 15 minutes closed 
will continue until the start time of the night schedule.

Morning schedule is available anytime from 12:00AM until 
11:59AM.

Night schedule is available anytime from 12:00PM until 
11:59PM.

4.  Press “

PROGRAM ENTER”

 again to go to the 

“MON-FRI”

 

night schedule. Repeat the steps listed above for this and the 

“SAT-SUN”

 day and night schedules.

When you have finished programming your schedule (either the 

7-day version or the weekday/weekend split version), use the 
down “RH” button to highlight the EXIT option and then press 

“PROGRAM ENTER” 

to select it.

Running the Ventilation Program

Press and hold the 

“PROGRAM ENTER” 

button until the

 

“PROGRAM”

 screen appears.

Use the down 

“RH”

 button to highlight 

“RUN PROGRAM”

:

Then press 

“PROGRAM ENTER”

 to select it. The display will 

appear as follows:

 

4.0 Temperature Cutout Programming

Dehumidifiers produce heat when dehumidifying and depending 
upon outside conditions, the ventilation function may also 
introduce warm air. Some conditions may introduce enough 
heat to drive household temperatures up. The DEH 3000R 
temperature cutout feature disables all Ultra-Aire operations if 
household temperatures reach the cutout setpoint.

In most installations this feature will not need to be used (the 
cutout is factory set to 99°F). If a lower temperature cutout 
is desired, program the setpoint by pressing and holding the 

“PROGRAM ENTER”

 button until the 

“PROGRAM” 

screen 

appears. Press the up/down 

“RH”

 buttons until 

“TEMP 

CUTOUT”

 highlighted. Then press the

 “PROGRAM ENTER”

 

button again to select it. Now use the 

“RH”

 up or 

“RH”

 down 

buttons to adjust the setpoint. Press 

“PROGRAM ENTER”

 to 

return to the home screen.

9

DEH 3000R Dehumidifier & Ventilation System Controller

 Installation, Operation & Service Manual

Summary of Contents for Ultra-Aire DEH 3000R

Page 1: ...ASE LEAVE MANUAL FOR HOMEOWNER Dehumidifier Ventilation System Controller 2008 Therma Stor LLC Manual P N TS 506b P O Box 8680 Madison WI 53708 TOLL FREE 1 800 533 7533 www thermastor com sales therma...

Page 2: ...95 RH 5 Auxillary Relay Capacity 5 Amps 24VAC Temp Range Accuracy 30 90 F 2 Size 4 95 L x 1 06 W x 4 19 H 2 Installation Install the DEH 3000R control panel in a central area of the structure where it...

Page 3: ...e optional motorized damper that can be installed into a fresh air duct This damper provides the ability to control fresh air ventilation using the ventilation timer function of the DEH 3000R and the...

Page 4: ...C transformer that reads 0 volts between it and the Yellow air conditioning call for cooling wire The incorrect wire will give a 20 to 28 volt reading 2 Another Yellow wire must be added to the thermo...

Page 5: ...t again to switch the fan to the ON setting c Confirm that the Ultra Aire fan is ON Ultra Aire compressor must be OFF Ventilation damper if used should be CLOSED 6 Verify optional VENT operation if el...

Page 6: ...A flashing O before the SET POINT VENT OR FAN indicates the unit is in wait mode 3 2 Setting During the set up process if you make a mistake simply continue You can always go back to adjust the settin...

Page 7: ...an Setting and Operation Use the FAN button to change the fan operation There are 2 choices for fan operation ON or AUTO The factory preset is AUTO ON The fan in the Ultra Aire dehumidifier will run c...

Page 8: ...he display Release the button 2 Press the VENT button again to switch between OPEN and CLOSED 3 Leave the control alone for 10 seconds and your settings will be saved 3 9 Damper Operation and Ventilat...

Page 9: ...schedule Repeat the steps listed above for this and the SAT SUN day and night schedules When you have finished programming your schedule either the 7 day version or the weekday weekend split version u...

Page 10: ...splice connectors provided Avoid routing parallel to high voltage wiring Maintain a distance of 2 ft or more from high voltage lines 2 Sensor connection The sensor can be mounted to a wall or ceiling...

Page 11: ...ome effective after initial purchase of the Product by Customer Customer Responsibilities As a further condition to obtaining warranty coverage hereunder the Customer must send a valid warranty claim...

Page 12: ...t to change without notice No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Ther...