Read the installation, operation and maintenance instructions
carefully before installing and operating this device. Proper
adherence to these instructions is essential to obtain
maximum benefit from your Ultra-Aire 65H indoor air quality
system.
READ AND SAVE THESE INSTRUCTIONS
• The device is designed to be installed INDOORS IN A SPACE
THAT IS PROTECTED FROM RAIN AND FLOODING.
• Install the unit with space to access the front panel for
maintenance and service. DO NOT INSTALL UNIT WITH THE
FRONT PANEL INACCESSIBLE.
• Avoid directing the discharge air at people, or over the
water in pool areas.
• If used near a water source; be certain there is no chance
the unit could fall into the water or get wet. The unit should
also be plugged into a GFCI (Ground Fault Circuit Interrupt
outlet).
• DO NOT use the device as a bench or table.
• DO NOT place the device directly on structural members.
• A drain pan MUST be placed under the unit if installed
above a living area or above an area where water leakage
could cause damage (see local regularity code for more
information).
Read and Save These Instructions
WARNING!
— This symbol indicates
important instructions. Failure to heed them can result
in serious injury or death.
CAUTION!
— This symbol indicates
important instructions. Failure to heed them can result
in injury or material property damage.
1.
Intended Application for Ultra-Aire 65H
For the ideal installation, draw air from the central part of
the home and return it to isolated areas of the home like the
bedrooms, den, utility room, or family room. The ductwork of the
existing heating system can be used to supply air to the home.
2. Registrations
The Ultra-Aire 65H conforms to UL STD 474 and CSA
Standard C22.2 No.92.
3. Specifications
Part Number:
4027170
Blower:
190 CFM @ 0.0" WG
Power:
680 Watts @ 80°F and 60% RH
Supply Voltage:
110-120 VAC – 1phase – 60 Hz
Current Draw:
5.50 Amps
Energy Factor:
1.95 L/kWh
Operating Temp.:
Between 40°F and 95°F Max
Sized for:
Up to 1600 Sq. Ft. - Typical
Miniumum Performance at 80°F and 60% RH
Water Removal:
65 pints/day
Efficiency:
4.1 Pints/kWh
Air Filter:
MERV-11
Efficiency:
Standard 65% Efficient
ASHRAE Dust Spot Test
Size:
9" x 11" x 1"
Power Cord:
9', 110-120 VAC, Ground
Drain Connection:
3/4" Threaded MPT
Drain Hose:
5/8" ID x 8'
Dimensions
Unit
Shipping
Width:
21"
27"
Height:
12"
17"
Depth:
12"
17"
Weight:
55 lbs
59 lbs
4. Installation
4.1 Installation Checklist
CAUTION
Prior to installation of the Ultra-Aire 65H, the following
checklist should be reviewed. The Ultra-Aire 65H can be
installed in a variety of locations to meet the owner’s needs,
and be integrated with existing forced air systems or existing
ductwork if desired. The location choice is contingent on
a variety of requirements not limited to: ease of service,
controls access, drainage, filtration, power, fresh-air
ventilation (optional), water damage prevention, and current
regulatory codes (ASHRAE, fire, etc). Please address all of
these issues before you select the location of the device.
n
4.1A Power Accessibility
Unit should be located in an area where the cord’s length (8')
should easily reach a 110-120 VAC electrical outlet with a
minimum of a 15 A circuit capacity.
SAFETY PRECAUTIONS
3
Ultra-Aire 65H Installer’s & Owner’s Manual