background image

SANTA FE ELITE MUFFLER KIT INSTRUCTIONS

12

Santa Fe Elite Installer’s & Owner’s Manual

Component List
(1) Silencer
(1) #8-18 Screw
(1) Instructions

Note: Washer and (2) screws are not 
used on the Santa Fe Elite.

Loosen these (2) screws 
enough to slide the silencer 
under the screw heads.

Insert (1) screw from the 
enclosed parts and tighten.

Santa Fe Elite Muffler Kit 
Installed

On the Santa Fe Elite, the muffler kit 
and condensate pump kit may be 
used together, but the pump will not 
be able to be mounted to the unit.

Summary of Contents for Santa Fe Elite

Page 1: ...safety instructions warranty information and all ancillary products n Read and save these instructions For small usage 420l Lien Rd Madison WI 53704 TOLL FREE 1 800 533 7533 www thermastor com sales S...

Page 2: ...20 Blower 275 CFM 0 0 WG Power 700 watts 80 F and 60 RH Supply Voltage 115 volt 1 phase 60 Hz Current Draw 6 4 Amps Operating Temp 56 F Min 95 F Max Sized for 2 500 Sq Ft Typical Minimum Performance a...

Page 3: ...ditional humidity control may need to be mounted in the humid area and wired to the Santa Fe Elite to accurately maintain the desired humidity Local electrical codes must be followed when wiring the c...

Page 4: ...passes through a filter drier and capillary tubing which cause the refrigerant pressure and temperature to drop It next enters the evaporator coil where it absorbs heat from the incoming air and evap...

Page 5: ...ompressor terminals C and R No continuity indicates an open run winding The compressor must be replaced Normal run winding resistance is 5 to 2 ohms 6 Compressor terminal C and overload terminal 1 No...

Page 6: ...and then charge the system with the quantity and refrigerant listed on the nameplate 8 Operate the system for a short period of time monitoring the suction pressure to determine that the suction filt...

Page 7: ...6 Wiring Diagram SANTA FE ELITE WIRING DIAGRAM 7 Santa Fe Elite Installer s Owner s Manual Figure 2 Electrical Schematic of the Santa Fe Elite Dehumidifier...

Page 8: ...4025741 1 Defrost Thermostat 4021648 1 Defrost Control Mounting Clip 12 4028225 1 Evaporator Coil 13 4029510 1 Filter Drier 14 4021626 1 Hose Drain 56 ID x 8 15 4021469 1 Humidity Controller 16 402149...

Page 9: ...5 Insert a romex connector or conduit connector into the hole in the cabinet that is left after the dehumidistat is removed Pass the cable to be used to connect to the remote dehumidistat through the...

Page 10: ...are located near the bottom and on the same side of the unit as the drain hose STEP 5 Example of hose cut at a 45 angle The angle prevents the hose from sealing tight against the bottom of the pump re...

Page 11: ...ach the inlet to the guides 4 Replace the filters in the unit Exhaust Collar Mounting Instructions 5 The six inch opening may be used as a fresh air inlet from outside 6 Remove the exhaust collar from...

Page 12: ...r and 2 screws are not used on the Santa Fe Elite Loosen these 2 screws enough to slide the silencer under the screw heads Insert 1 screw from the enclosed parts and tighten Santa Fe Elite Muffler Kit...

Page 13: ...s Owner s Manual Instructions To prevent damaging the foam filter place it grid side up on top of the pleated filter and slide them both into the filter slot Foam filter with plastic grid up Pleated f...

Page 14: ...ent that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Responsibilities As a further condition to obtaining warr...

Page 15: ...uced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2008 Therma Stor LLC All rights reserved 4201 Lien Rd...

Page 16: ......

Reviews: