2
www.UsePhoenix.com • [email protected]
Toll-Free 1-800-533-7533
1 Specifications
Part No.
4028600
Power
110-120 Vac, 8.9 amps
Water
161 pints/day @ AHAM (80°F, 60%)
Removal
Refrigerant
2 lbs. 1 oz. R410a
Charge
Blower
380 CFM
Internal Condensate Pump with 20’ lift,
30’ vinyl hose
Operating
33°F to 125°F
Range
Filters
16” x 20” x 2” Pleated Media MERV-11
Duct
Intake – 12” Flex-Duct
Options
Exhaust – 10” Lay-Flat
Warranty
Five years;
First year 100% of Parts and Labor
Second-fifth year 100% of Parts of sealed
refrigeration system.
Dimensions
Width 20”, Height 40”, Depth 23”
Weight
130 lbs.
2 Operation
2.1 Transporting the Phoenix 270HTx
The Phoenix 270HTx must always be upright when
transported by vehicle. It may be tipped on to its handle
and back for loading and moving by hand.
2.2 Location
Note the following precautions when locating the Phoenix
270HTx:
• It is designed to be used
INDOORS ONLY.
• If used in a wet area, plug it into a
GROUND FAULT
INTERRUPTER
.
•
DO NOT
use the Phoenix 270HTx as a bench or table.
• It must always be used in the upright position.
• The air inlet on top & the side outlet must be at least
1 foot from walls and other obstructions to air flow.
Table of Contents
Introduction
................................................................1
1. Specifications
........................................................2
2. Operation
.............................................................2
2.1 Transporting the Phoenix 270HTx .....................2
2.2 Location .........................................................2
2.3 Electrical Requirements ...................................3
2.4 Condensate Removal .......................................3
2.5 Ducting ...........................................................3
2.6 Power Switch ..................................................3
2.7 Pump Purge Switch ..........................................3
2.8 Hour Meter .....................................................3
2.9 Defrost Control Adjustment ..............................3
2.10 Hours Button ................................................3
2.11 Defrost Light .................................................3
2.12 Low Pressure Control .....................................3
2.13 Automatic Bypass Control ..............................4
3. Maintenance
.........................................................4
3.1 Air Filter ..........................................................4
3.2 Storage ..........................................................4
4. Service
.................................................................4
4.1 Technical Description .......................................4
4.2 Troubleshooting ...............................................5
4.3 Air Mover Replacement ....................................6
4.4 Thermistor Replacement ..................................6
4.5 Condensate Pump Replacement .......................6
4.6 Refrigerant Charging ........................................6
4.7 Compressor/Capacitor Replacement ................6
4.8 Gravity Drain Option .........................................6
4.9 Relay ..............................................................6
5. Wiring Diagram
.....................................................7
6. Service Parts List
..................................................8
Warranty
.............................................................10
Serial No. ___________________________
Purchase Date ______/______/_____
Dealer’s Name ___________________________________
Read the operation and maintenance instructions
carefully before using this unit. Proper adherence to these
instructions is essential to obtain maximum benefit from
your Phoenix 270HTx dehumidifier.
• It is designed to be used
INDOORS ONLY
.
• If used in a wet area, plug it into a
GROUND FAULT
INTERRUPTER
.
•
DO NOT
use the Phoenix 270HTx as a bench or table.
• It must always be used in the upright position.