background image

9

www.thermastor.com • [email protected]

Toll-Free 1-800-533-7533

Item   Part No.  

Qty.   Description

 

4022254 

 

Accumulator 

 

402475 

 

Air Filter, Pleated, 2” x 6” x 20” 

 

 

 

65% Merv-

4024682 

 

Air Filter, Pleated, 2” x 6” x 20” 

  

 

 

57% MERV-8 (optional)

 

4022489 

 

Air Filter, Pleated, 4” x 6” x 20” 

 

 

 

95% Mini-Pleat MERV-4 (optional) 

4022037 

 

Blower

402589 

Capillary Tubes,  

 

 

 

.050” ID x .4” OD x 28” long

4023390 

 

Compressor Kit, Carlyle 

 

 

 

(P/N EAA090A)

 

4022476 

 

Overload, Carlyle Cprsr 

 

 

 

(included with compressor kit)

402483 

 

Cord

4023080 

 

Coupling Insert, .38 Tube 

402470 

 

Defrost Thermostat

 

402648 

 

Defrost Thermostat Mounting Clip

402395 

 

Evaporator Coil

4020955 

 

Filter/Drier

 

4024073 

Foot

4026094 

 

Handle Assembly

402597 

 

Hour Meter

402498 

 

Instruction Label

402229 

 

Low Pressure Control 

402796 

 

Pump Purge Switch

402822 

 

Power Switch

4024903 

 

Top

Item   Part No.  

Qty.   Description 

***** 

 

Wheel/Axle Assembly

 

4026304 

Wheel, 2”

 

4024904 

 

Axle

 

4025454 

E-Ring

20 

4024078 

 

Wire Duct Collar (Exhaust)

4025043 

 

Skid Panel

Items listed below are not shown

22 

4023649 

 

Condensate Pump

23 

402396 

 

Condenser Coil

24 

402490 

 

Coupling Body, .25 Tube 

25 

402823 

 

Defrost Timer

26 

402496 

 

Drain Hose (.25 ID x 33’ long) 

27 

09600 

 

Front Panel Screw, /4-20 x  

28 

205473 

 

Front Panel Retaining Nut, /4 –20

97000 

 

Relay

32 

402492 

 

Run Capacitor, 35 MFD, 370 Vac 

6 Service Parts

18

2

1

9

7

8

10

4

5

3

20

6

15

19

11

14

17

13

16

12

Figure 4

Specifications subject to change without notice.

Summary of Contents for Phoenix 200 MAX

Page 1: ...s for drying areas to much lower humidity levels than conventional dehumidifiers The Phoenix 200 MAX an improved version of the original Phoenix 200 is the culmination of over a decade of LGR manufact...

Page 2: ...e used INDOORS ONLY If used in a wet area plug it into a GROUND FAULT INTERRUPTER DO NOT use the Phoenix 200 MAX as a bench or table It must always be used in the upright position Read the operation a...

Page 3: ...ft in the condensate pump reservoir for moving or storage Pressing and holding the pump purge switch will cause the condensate pump to run Hold the switch in until the flow from the condensate hose st...

Page 4: ...ain it completely Walk under out of the hose to open end If the unit will not be exposed to freezing temperatures an alternative to reduce biological growth is to flush the unit with a bio fungicide t...

Page 5: ...r but not as much as expected 1 Air temperature and or humidity have dropped 2 Humidity meter and or thermometer used are out of calibration 3 Unit has entered defrost cycle Sec 2 9 4 7 4 Air filter d...

Page 6: ...motor the compressor must be replaced 9 Disconnect the wires from the capacitor Set the ohmmeter to the Rx1 scale the capacitor is shorted and must be replaced if continuity exists across its terminal...

Page 7: ...tween the accumulator and compressor If the low side refrigerant temperature drops due to excessive frost formation on the evaporator coil the thermostat opens The compressor is then cycled off and on...

Page 8: ...www thermastor com sales thermastor com Toll Free 1 800 533 7533 Figure 3 Electrical schematic of 200 MAX 5 Wiring Diagram...

Page 9: ...1 Filter Drier 11 4024073 2 Foot 12 4026094 1 Handle Assembly 13 4021597 1 Hour Meter 14 4024918 1 Instruction Label 15 4022219 1 Low Pressure Control 16 4021796 1 Pump Purge Switch 17 4021822 1 Power...

Page 10: ...10 www thermastor com sales thermastor com Toll Free 1 800 533 7533 This page intentionally left blank...

Page 11: ...rmal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installat...

Reviews: