SAFETY AND DANGERS      

2.

SAFETY AND DANGERS

Dangers

Before beginning the training, consult a doctor or therapist to clarify whether 

users with cardiovascular diseases are allowed to exercise with the THERA-

Trainer coro. 

Only exercise under supervision of a trained assistant.

Ensure that belt buckles audibly click into place.

In case of possible infection due to contaminated attachments/optional parts, 

always wear personal protective equipment (gloves, mask) when cleaning 

THERA-Trainer coro.

Warning

Observe the user manual.

Disinfect THERA-Trainer coro before every training.

Regularly check screws for firm seat.

Always use the THERA-Trainer coro with pelvic safety strap or fall protection 

belt incl. seat board, if an assistant is not available to prevent falling.

In case of damage, malfunctions, etc. to the THERA-Trainer coro, contact the 

trained supplier immediately.

Before every training with a pelvic safety strap or fall protection belt incl. seat 

board, ensure that these are properly put on and secured.

Before every training with a simple knee support, ensure that this is properly 

secured.

Before every training, ensure that the balance unit is functioning properly.

Service or repair work is only to be carried out by trained suppliers.

Caution

Prior to the initial start-up, have the specialist dealer, doctor or therapist show 

you or your assistant how to use the product.

Before starting the training, consult a doctor or therapist and clarify whether 

THERA-Trainer coro can be used without assistance. 

Set spring resistance of the THERA-Trainer coro to fit the user's activity, height 

and body weight.

If any symptoms of illness occur during or after the training, consult a doctor 

immediately. 

Select range of movement according to the user's therapy goals. 

Use THERA-Trainer coro only in undamaged and functional condition. 

Use THERA-Trainer coro on even and slip-proof floor.

The manufacturer recommends only using the THERA-Trainer coro with clo-

sed footwear (user and assistant). 

Ensure that no fingers get jammed when making adjustments to the THERA-

Trainer coro.

Ensure that before stepping into the THERA-Trainer coro all double steering 

castors are blocked. 

Ensure that before and during the training, the tread unit does not get wet. 

Ensure that before stepping into the THERA-Trainer coro the balance function 

is locked. 

Do not use THERA-Trainer coro to transport persons. 

Only use control and display unit/computer with undamaged and functioning 

cables. 

Always supervise children during training. 

Keep animals and playing children away from THERA-Trainer coro. 

Summary of Contents for CORO

Page 1: ...USER MANUAL THERA TRAINER CORO English translation of original user manual...

Page 2: ...th tips and information on how to use your new exerciser best Before starting the unit for the first time please read and observe chapter 2 Safety and dangers If you have any further questions or comm...

Page 3: ...stalling the THERA Trainer coro 17 7 4 Transport THERA Trainer coro 18 7 5 Start up 18 8 OPERATION 18 8 1 Exercise preparation 19 8 2 Upper pipe frame 19 8 3 Cushion set for upper pipe frame 21 8 4 Si...

Page 4: ...THERA Trainer coro User manual 4 Art no A005 962_Rev 01 Last update CW34 2016 12 TECHNICAL DATA 34 13 DISPOSAL 35 14 WARRANTY 35...

Page 5: ...uctions Structure of instructions Instruction to do something Presentation of results if required SIGNAL WORD Type and source of danger Action to avoid the danger DANGER Indicates an immediate risk wh...

Page 6: ...l 1 List level 2 Structure of numbered lists 1 List level 1 2 List level 1 2 1 List level 2 2 2 List level 2 1 4 Symbols on the product Observe the user manual Manufacturer year Follow the user manual...

Page 7: ...is functioning properly Service or repair work is only to be carried out by trained suppliers Caution Prior to the initial start up have the specialist dealer doctor or therapist show you or your assi...

Page 8: ...hot environments Do not smoke while exercising Use exclusively the manufacturer s original parts Use exclusively the options listed by the manufacturer Use exclusively cleaning agents and disinfectant...

Page 9: ...mobility in the ankle through daily exercises For maintaining or improving mobility and muscle power For stimulating metabolism and circulation For the use in facilities e g clinics homes therapy pra...

Page 10: ...When exercising by himself bears full responsibility for ensuring that the THERA Trainer coro is used safely and correctly Before the first training Be instructed by a trained supplier doctor or thera...

Page 11: ...users with extreme osteoporosis users with imperfect osteogenesis Osteogenesis imperfecta users with unstable circulation e g due to being bedridden for a lengthy time users who cannot place some wei...

Page 12: ...Pelvic safety strap Can be fixed on the upper pipe frame with two belt buckles Washable and disinfectable OR Fall protection belt incl seat board Can be fixed on the upper pipe frame with two belt bu...

Page 13: ...play unit with 11 6 colour screen THERA soft SB feedback sensor type A incl touch button Bluetooth receiver for sensors feedback sensor fixing set for THERA Trainer coro USB power supply for feedback...

Page 14: ...arts of THERA Trainer coro Name Article no Tread extension connection part magnetic A004 915 Tread extension mid part magnetic A004 916 Tread extension ramp magnetic A004 917 Simple knee support A002...

Page 15: ...e CW34 2016 THERA Trainer coro User manual SCOPE OF DELIVERY AND EQUIPMENT Hip cushion short left A005 288 Hip cushion short right A005 289 Arm support cushion A002 428 Table for THERA Trainer coro 46...

Page 16: ...ea for mouse and keyboard 8 Vertical pipe of balance unit 9 Mobile holder for control and display unit 10 Feedback sensor type A incl touch button 11 Release lever for balance function 12 Isolation tr...

Page 17: ...floors Do not use the THERA Trainer coro outside or in outdoor facilities 7 3 Installing the THERA Trainer coro Connect feedback sensor type A incl touch button Clip the feedback sensor A incl touch b...

Page 18: ...when cleaning and disinfecting Observe general precautions to prevent users from being exposed to blood borne pathogens Wear personal protective equipment gloves masks lab coats when contact to bodily...

Page 19: ...UTION Risk of injury due to tipping over or slipping of the THERA Trainer coro Place THERA Trainer coro on even and slip proof floor Ensure that all four double steering castors are blocked Place chai...

Page 20: ...just height on second vertical pipe Ensure that the height on the left vertical pipe and right vertical pipe of the upper pipe frame is adjusted the same Adjusting the broad stay tubes Pull out safety...

Page 21: ...off Before every training ensure that the simple knee support is secured with both ball catch pins WARNING Risk of injury due to incorrectly adapted simple knee support Prior to every training sessio...

Page 22: ...t height on second vertical pipe Ensure that height on the left vertical pipe and right vertical pipe are the same Removing the simple knee support Remove simple knee support 1 before the user is stan...

Page 23: ...e pelvic safety strap press both release buttons on the belt buck les 1 For cleaning and disinfecting see chap 10 Cleaning and disinfection Belt buckles can only be opened if these are not under load...

Page 24: ...tly In particular if no assistant is available to prevent falling Ensure that the belt buckles are properly engaged Never train without belt system being correctly connected if a person is not present...

Page 25: ...dibly click into place Ensure that the belt of the pelvic safety strap marked blue 5 runs according to the applicator 3 over the stay tubes Ensure that the belt of the seating board marked orange 8 ru...

Page 26: ...ic arm on the upper pipe frame and secure with Velcro straps If necessary clean and disinfect arm support cushion 8 8 Table for THERA Trainer coro 460 x 700 mm The table enables use of arm support sys...

Page 27: ...d to be used however the connection part must be used to use the additional tread extensios WARNING Risk of injury due to wheelchair tipping over Install all segments of the tread extension on even an...

Page 28: ...RA Trainer coro without tread extension 8 10 Setting balance function Set release lever 1 to position 0 1 or 2 on both vertical pipes Position 0 balance function disabled 4 Position 1 balance function...

Page 29: ...hat transport castors are blocked Move user with chair or wheelchair directly behind THERA Trainer coro Secure wheelchair to prevent it from moving When exercising in an electric wheelchair switch off...

Page 30: ...fety belt should be used 8 13 Safety equipment Remove pelvic safety strap or fall protection belt incl seat board Ensure that these are not damaged Especially pay attention that the seams are in prope...

Page 31: ...rapist or trained supplier if you have any questions problems During the training Start training slowly Increase the training to 70 of individual performance limit Avoid over strain e g over stretchin...

Page 32: ...ls which are to be changed after every use Use exclusively alcohol based watery disinfectants ascending order of effi ciency methanol ethanol isopropanol n propanol for wipe disinfections Clean disinf...

Page 33: ...arm soapy water and a microfibre cloth or a soft hand brush To disinfect place pelvic safety strap seating board cover in an alcohol based watery disinfectant solution and disinfect Disinfect the fall...

Page 34: ...cl seat board Furthermore the manufacturer recommends performing a technical check The corresponding information for the technical check is available from the manufactu rer upon request 12 TECHNICAL D...

Page 35: ...r s warranty for the THERA Trainer coro if it is handled with due care The basis is the date of delivery Within this period of time the manufacturer will replace free of charge any faulty parts of the...

Page 36: ...intechnik GmbH Blumenweg 8 88454 Hochdorf Germany Tel 49 7355 93 14 0 Fax 49 7355 93 14 15 Email info thera trainer de Internet www thera trainer de Article no A005 962_Rev 01 Last update CW34 2016 Se...