Please read these instructions thoroughly before use. Failure to follow instructions may result in 

equipment damage or failure, losses, injury or death.

 DANGER: 

To avoid possible electric shock:

• If the power cord has been damaged, DO NOT operate. The MagFlo Pump should be replaced. 
• Close supervision is necessary when the unit is used by or near children.

 WARNING: 

To reduce the risk of electric shock:

• Connect only to a properly grounded receptacle, which is serviced by a Ground Fault Circuit 

Interrupter, and never remove the ground pin from the plug. 

• Provide a “drip loop” for the power cord. A drip loop is a downward-

facing loop in the power cord, falling below the level of the electric 

receptacle and plug, which prevents water from traveling along the cord 

in the direction of the receptacle. 

• ALWAYS unplug the MagFlo Pump from power source when it is not in 

use.

• ALWAYS unplug the MagFlo Pump from power source before installing, 

removing or servicing the MagFlo Pump components.

• If an extension cord is necessary, a cord 14 gauge up to 100 ft. must be 

used. A cord may overheat if the cord is rated for less amperes or watts 

than the unit rating.

• DO NOT immerse the MagFlo Pump plug in water or attempt to use a wet plug. 
• The MagFlo Pump is NOT suitable for use in swimming pools, swimming ponds, or other situations 

where bodily contact is made with the water. 

Important – This unit is equipped with a permanent magnet. The magnetic field may affect the 

function of pacemakers.

 CAUTION: 

To reduce the risk of equipment damage or failure:

• ONLY use the MagFlo Pump in fresh water applications.
• DO NOT place MagFlo Pump near flammable or other dangerous materials or objects.
• ALWAYS unplug the unit if there is no water running through it to prevent overheating.
• DO NOT run the pump dry.
• DO NOT operate during freezing conditions. Drain MagFlo Pump and store in a protected location. 

  

The Pond Guy is not responsible for equipment damage or failure, losses, injury or death resulting from 
failure to follow safety precautions, or from misuse or abuse of equipment.

Power Cord

Drip Loop

thepondguy.com  |  866-POND-HELP (766-3435)  

2

Summary of Contents for MagFlo Series

Page 1: ... TM ImportantInformation 2 PackageContents 3 InstallingYourMagFloPump 4 6 MaintainingYourMagFloPump 6 8 Troubleshooting 8 ReplacementParts 8 TechnicalSpecs 8 WarrantyInformation 8 Table of Contents For Model MagFlo 290 Item 120930 ...

Page 2: ...ing the MagFlo Pump components If an extension cord is necessary a cord 14 gauge up to 100 ft must be used A cord may overheat if the cord is rated for less amperes or watts than the unit rating DO NOT immerse the MagFlo Pump plug in water or attempt to use a wet plug The MagFlo Pump is NOT suitable for use in swimming pools swimming ponds or other situations where bodily contact is made with the ...

Page 3: ...uri adapter and run the airline tube outside the waterbody airline tube length will vary depending on pond size MagFlo Pump Package Contents A 1 MagFlo Pump E 2 Outlet Male Tubing Adapters B 4 Rubber Feet F 1 Venturi Adapter C 1 Flow Control Valve G 1 Volcano Spray Pattern D 3 Fountain Extension Tubes H 1 Water Bell Spray Pattern B F D C G H A E thepondguy com 866 POND HELP 766 3435 3 ...

Page 4: ... tube D 4 Continue to Step 2 Waterfall Feature 1 Attach outlet male tubing adapter E or F to pump outlet of MagFlo pump A 2 Connect and secure your pond tubing to tubing adapter E or F with a hose clamp not included 3 Connect pond tubing to your waterfall or water feature 4 Continue to Step 2 For Best Results MagFlo Pump should be placed on a flat surface away from sludge or algae mats DO NOT run ...

Page 5: ...lo pumps in line out of the water to power a waterfall feature only but the pump must be placed below the water level MagFlo pumps must be set up with a flooded suction intake and will not suction lift 1 Remove pump intake screen pre filter sponge and impeller screen 2 Connect one outlet male tubing adapter E to pump intake and one to pump discharge of MagFlo Pump A Connect and secure your pond tu...

Page 6: ...ump and detach from pond tubing Remove fountain assembly if applicable Move pump to a dry workspace CLEANING THE PUMP Tools Required Damp Cloth or Small Brush Descaler such as Airmax D Scale Step 2 Remove Pre Filter Pull firmly to remove the pump pre filter from the pump motor thepondguy com 866 POND HELP 766 3435 Step 5 Adjust Fountain Spray For the water bell fountain spray pattern H it may be n...

Page 7: ...g and re installing impeller Step 5 Clean Impeller Fountain Clean impeller and impeller chamber with water Remove and disassemble fountain connections and tubing adapters Wash thoroughly with water A small brush or descaler may be helpful If using a descaler be sure to rinse all parts with clean water before reassembly Step 6 Reassemble Pump Reassemble impeller impeller cover impeller screen pre f...

Page 8: ...3435 thepondguy com V1 MAGFLO PUMP MODEL REPLACEMENT IMPELLER REPLACEMENT FILTER SPONGE REPLACEMENT FOUNTAIN KIT MagFlo 290 120939 120948 120956 TECHNICAL SPECS MODEL VOLTAGE WATTAGE CORD GPH 3 HEAD MAX HEAD DISCHARGE INLET FITTING MagFlo 290 120V 60 Hz 17Watts 20 197 GPH 6 5 TROUBLESHOOTING Pump does not turn on Check that the power cord is connected Check to see if the GFCI or main circuit break...

Reviews: