A. Important remarks

Thank you for choosing our products. Before installation, it is strongly recommended to read
this instruction firstly. This manual includes the information of installation, debugging,
running and maintenance of the products.

Every unit of products has passed strictly test to ensure safety and high efficiency operation.

The manufacturer of this product will not be held responsible if someone is injured or the unit
is damaged, as a result of improper installation, debugging, and unnecessary maintenance
which is not in line with this manual.

The installer should be an authorized technician, and install the system follow the diagram
on the equipment.

Please notice the following information during installation:

1. Applied working temperature of heat pump: -7~43

.

2. Check whether the power supply and wire meet the standard of the unit.
3. Do not alter the power wire or socket and the metal parts should be connected to GND well. Do

not change the GND connection of the system.

4. The appliance shall be installed in accordance with national wiring regulations.
5. When the system is connected to a fixed power supply, a 3mm space switch should be equipped.

At the same time, must connect a power leakage protector. (30mA, 0.1sec.)

6. When finish all the wiring, check it again before power on.
7. Do not install the system in the warehouse where flammable gas may leak out.
8. Do not insert hands or object into the vent of the heat pump, it may cause the dangerous to

people or damage the system.

9. To make the system more efficiency, please install the main unit at a place with good ventilation.
10. Do not put (or install) the operating panel at a wet place, do not cut and reconnect the

connecting wire.

11. Before turn on the system at a first time, ensure the water tank is full filled with water.
12. The inlet of the water tank equips with a filter (detachable), clean it according to the water quality

and running condition of the system (the period should be 2~3 months)

13. While the water supply has been stopped or the system stops running for a long period in winter,

should be drain the tank water to avoid water system frost crack.

14. The highest temperature of outing water is 60

, when using, tune up to a suitable temperature

(the most suitable temperature for human is 38

45

, if the temperature is higher than 55

, it

may cause the danger of scald). Normally, the setting temperature can be from 10

- 55

, the

model with Auxiliary heater can reach up to 70

.

15. Move the main unit at max. 30 degree angle. Do not drop down or upend the unit.
16. Maintain the system by an authorized technician. And disconnect all power when servicing.
17. The water quality requirements for the heat pump: Chloride content in the water should be

<250mg/L; the PH of the water range is 6.5~8.5; the Calcium carbonate saturation index in the
water range is 1.0~0.4. Warranty does not apply to the heat exchanger, electrical heater and
water tank if it s connected to water quality out of the range.

18. Please provide the warrantee card and S/N No. enclosed with the product for after service.

Summary of Contents for RS-3.6FAD/260LX9

Page 1: ...ALL IN ONE Heat Pump Water Heater INSTALLATION AND OPERATION INSTRUCTIONS Please read this user s manual carefully before operate the unit...

Page 2: ...t the unit is STOP operation when disconnecting the power supply to the unit Disconnect all electric power supplies before servicing 3 This appliance is not intended for use by persons including child...

Page 3: ...heat pump it may cause the dangerous to people or damage the system 9 To make the system more efficiency please install the main unit at a place with good ventilation 10 Do not put or install the ope...

Page 4: ...2 B Description of heat pump Unit constructions outside...

Page 5: ...Electric Heater hole is only for the unit with Auxiliary heater models other models without auxiliary heater function are not available 3 There are two Circulation Water Hole for optional connection...

Page 6: ...ction 3 If install as Fig 2 the unit can be installed by the middle of the wall and connect the air inlet and outlet pipe for air exchange The distance of the unit and wall or other obstacle should no...

Page 7: ...pe The safety valve should be connected by a small rubber pipe interlinked with atmosphere this pipe must not be blocked in order to drain the water when the tank s pressure exceeds 0 7MPa 14 Water in...

Page 8: ...de by themselves 3 Before installation it s better to reserve a water supply pipe interface hot water outlet pipe interface and drainage pipe interface Among them the water supply pipe and hot water o...

Page 9: ...7 D Operation panel instruction 1 Panel Operation...

Page 10: ...8 D Operation panel instruction 2 Panel Display Cloud icon flashing during the connect with the internet always lighting after connected with the internet no lighting means no cloud control function...

Page 11: ...temp amendment 5 5 0 C Compressor F21 Compressor start delay 0 10 3 minute F28 Econ mode turn on or off electric heater 0 1 1 F29 Heat pumps working or not in heater mode 0 1 1 Defrost F31 Defrost sta...

Page 12: ...ctronic expansion valve EEV F70 EEV opening query 0 480 F71 EEV control mode 0 2 0 F72 Manually set EEV opening 100 480 350 F73 Set EEV superheat degree 15 15 5 F74 Set EEV discharge temp 85 110 92 F7...

Page 13: ...r temp is too high 2 Change the Electric heater A7 Exhaust temperature too high 1 Lack of refrigerant 2 Mix with air in system 3 Lack of lubricating oil 1 Supply refrigerant 2 Re vacuumizing and fill...

Page 14: ...ration for a long time there may have condensation water hereabout the air outlet or pipe especial in humidity weather this is a normal phenomenon use a dry washcloth to clean it or by air dry 6 The a...

Page 15: ...ation panel back panel and top cover of the unit follow the below steps Fig 5 6 to process Fig 5 Fig 6 Top cover disassemble Remove all the item 2 screws of the top cover 1 push up the top cover verti...

Page 16: ...ig 7 Fig 8 2 Loose the power wire from the terminal block to avoid the wire get stuck when move up the top shell 3 Remove all the screws item 2 from the Back panel item 5 two sides decoration bar item...

Page 17: ...ump without auxiliary electric heater 2 1 Comp Fan Valve Elect R S C BLACK 12V RED 220V 5 COMPRESSOR LOW HI BXS N LOW PRESURE PROTECTOR HI PRESURE PROTECTOR RETURN GAS TEMP SENSOR EXHAUST TEMP SENSOR...

Page 18: ...OWER SUPPLY YELLOW GREEN Transformer WATER TEMP SENSOR OPERATION PANEL ELECTRIC HEATER YELLOW GREEN 4 WAY VALVE FAN MOTOR YELLOW GREEN ELECTRIC HEATER PROTECTOR PRESURE PROTECTOR Electronic expansion...

Page 19: ...17 G Annex list ITEM NAME SPECIFICATION QUANTITY REMARK 1 Safety valve 1 2 Manual 1...