CoolShell CS-3U Installation Manual
1-6
Themis Computer
1.3
Specifications
1.3.1
General
lists the general specifications for the CoolShell CS-3U.
1.3.2
Environmental
The CoolShell CS-3U is designed to meet the environmental requirements listed in
Table 1-1.
General Specifications
Parameter
Operating
Non-Operating
Dimensions
0° to 50° C
–40° to 80° C
CoolShell CS-3U Weight—Average
(without Storage Expansion Subsystem)
CPU Blade
I/O Blade
Media Module
Power Supply (PS)
Subrack
Storage Expansion Subsystem
39.76 pounds (1 PS)
to 42.52 (2 PS) pounds
13.0 pounds
9.5 pounds
4.5 pounds
2.76 pounds
10 pounds
6.9 pounds
N/A
Reliability
16,800 hours without failure
N/A
Table 1-2.
Environmental Specifications
Parameter
Operating
Non-Operating
Temperature
0° to 50° C
–40° to 80° C
Humidity (non-condensing)
0% to 95%
0% to 95%
Atmospheric Pressure
87.0 to 108.4 kPa
57.2 to 108.4 kPa
Altitude
0 to 10,000 feet above sea level
0 to 40,000 feet above sea level
Shock
25G
25G
Vibration
3G (rms), 10 Hz to 28 Hz (MIL167-1)
3G (rms), 10 Hz to 28 Hz (MIL167-1)
Airflow
240 CFM
N/A
Summary of Contents for CoolShell CS-3U
Page 16: ...xiv Themis Computer CoolShell CS 3U Installation Manual...
Page 22: ...xx Themis Computer CoolShell CS 3U Installation Manual...
Page 40: ...2 8 Themis Computer CoolShell CS 3U Installation Manual...
Page 52: ...A 12 Themis Computer CoolShell CS 3U Installation Manual...
Page 90: ...CoolShell CS 3U Installation Manual B 38 Themis Computer...
Page 110: ...C 20 Themis Computer CoolShell CS 3U Installation Manual...