Page | 92
Time-controlled urinal flushing
Regular, flushing of urinals according to requirements are, for hygienic reasons, necessary for
restaurants, bars and discos.
A water-saving and economic solution is offered by the TR 611 top2 time switch with its time-controlled
cycle program.
Depending on the weekday and visitor frequency, the flushing cycles in the urinals can be optimally
adapted. According to time control e.g. during opening hours there are flushing cycles in 10-minute
intervals for a duration of 20 seconds. The individual setting possibility according to the weekday and
visitor frequency enables the optimisation of the flushing times and, thereby, a reduction in water
consumption.
15 Technical data
Minimum loads:
o
230 V AC: 10 mA
o
24 V DC: 100 mA
o
The minimum load is required to ensure that the relay contacts do not get dirty.
15.1 TROUBLESHOOTING
Problem/fault
behaviour:
Hour setting 11:00 pm for sum-win "free setting" and "fixed date" is not
possible.
Cause:
Given that the day transfer is not permitted for the sum-win changeover (time
change forwards or backwards) no selection of the changeover hour 11:00
pm is possible.
Solution:
Select sum-win changeover at 10:00 pm or 00:00 midnight (see page 32)
Problem/fault
behaviour:
"The sum-win changeover does not work correctly in Australia"
Cause:
The changeovers in the Southern Hemisphere are exactly the opposite.
Solution:
Use the free setting and for the sum-win changeover select the date from the
first half year (e.g. March) and for the win-sum changeover use the date from
the second half year (e.g. October) (see page 32-33)
Problem/fault
behaviour:
"OBELISK top2 does not start when inserting."
Causes:
PIN is activated; incorrect OBELISK top2; time switch is not in the auto
mode.
Solution:
Do not set ANY PIN. If the PIN number has been forgotten contact the
Theben hotline.
Return to the auto mode using the ESC push button (see pages 51-52)
Problem/fault
behaviour:
"When OBELISK top2 is inserted, the two left-hand push buttons do not
operate."
Cause:
Since they are difficult to access these push buttons have no function as
long as the OBELISK top2 is inserted.
Solution:
None. Only the two right-hand push-buttons can be used
(see page 58)
Problem/fault
behaviour:
"OBELISK top2 displays ERROR on the time switch before overwriting."