background image

22

ENGLISH

Note:

Checking, clearing or cancelling a holiday program is described

in section 4.8 on page 20.

5.2

Changing the Settings for Target
Temperatures

For the temperature profiles of the individual programs, you can
choose between three temperature values: Comfort, lower and anti-
freeze temperature.

These temperature values are programmed ex works. You can
change these according to your wishes.

5.3

Program P3

5.3.1

Overview "Program" menu

5. The holiday program is now programmed and is activated at the

set start time.

6. Reset the rotary switch to the desired program and close the

hinged cover.

7. While the holiday program is active, the display shows the target

temperature and the text line

Holiday

.

1. Open the hinged cover and turn the rotary switch to the MENU

setting.

2. With the buttons

or

, select the entry

Target temp

. Confirm

with the

OK

button.

3. The display first shows the comfort temperature.

With the buttons

or

, change the comfort, lower and anti-

freeze temperature one after the other. Confirm each setting with
the

OK

button. The display changes automatically.

4. After having set the antifreeze temperature, the setting of the tar-

get temperatures is completed. The display shows

End

and auto-

matically changes back after 3 seconds.

5. Turn the rotary switch to the desired program and close the

hinged cover.

MENU

TARGET TEMP

Service

Holiday

PROGRAM

Clock/Date

OK

New

Check

Clear

End

see 5.3.2
see 5.3.3
see 5.3.4

5. The holiday program is now programmed and is activated at the

set start time.

6. Reset the rotary switch to the desired program and close the

hinged cover.

7. While the holiday program is active, the display shows the target

temperature and the text line 

Note: 

Checking, clearing or cancelling a holiday program is 

described in section 4.7 on page 22.

5.2

Changing the Settings for Target
Temperatures

For the temperature profiles of the individual programs, you can 
choose between three temperature values: Comfort, lower and 
antifreeze temperature.

These temperature values are programmed ex works. You can 
change these according to your wishes.

1. Open the hinged cover and turn the rotary switch to the MENU

setting.

2. With the buttons 

or 

, select the entry                     Confirm

with the 

OK 

button.

3. The display first shows the comfort temperature.

With the buttons 

or 

, change the comfort, lower and anti-

freeze temperature one after the other. Confirm each setting with 
the 

OK 

button. The display changes automatically.

4. After having set the antifreeze temperature, the setting of the tar-

get temperatures is completed. The display shows        and auto-
matically changes back after 3 seconds.

5. Turn the rotary switch to the desired program and close the

hinged cover.

5.3

Program P3

5.3.1

Overview “Program” menu

Holiday

.

Target temp

.

End

see 5.3.2
see 5.3.3
see 5.3.4

24

Summary of Contents for RAMSES 818 top

Page 1: ...rmostat Notice d utlilisation 31 Thermostat horloge Gebruiksaanwijzing 45 Klokthermostaat Istruzioni per l uso 59 Cronotermostato Instrucciones de uso 73 Termostato con reloj RAM 811 top TR 610 top RA...

Page 2: ...only be carried out by a qualified technician The national regulations and respective safety instruc tions are to be observed Interferences and changes to the device will lead to can cellation of the...

Page 3: ...e 20 0 C Display PARTY or ECO program active Display for batteries to be replaced only RAMSES 811 top Display of the switch phases RESET button 3 Description and Mounting 3 1 Device Overview Display o...

Page 4: ...terminal Now attach the connection cable see figure Heating cable test Press the Info key for approx 4 secs with heating cable connec ted until Test Mode appears in the display Test Mode remains dis p...

Page 5: ...OK button Deutsch English Francais Italiano Espanol NL OK Hour 0 00 OK Hour 15 00 OK Minute 15 34 4 Installation and Operation For installation of RAMSES 818 top follow the sections 4 1 to 4 5 4 1 Ca...

Page 6: ...Currently active target temperature Date and time Switch times of the set program only visible with opened hinged cover The fixed programmed temperature profiles and switch times are described in sect...

Page 7: ...am is cleared You can now program a new holiday program see section 5 1 on page 21 or set the desired temperature profile automatic program at the rotary switch see section 4 5 on page 19 4 6 Temporar...

Page 8: ...ou want the comfort the lower or the antifreeze temperature for the set period Confirm with the OK button 4 8 Party Eco Program With the Party Eco function you can cancel the temperature profile of th...

Page 9: ...d program and close the hinged cover MENU TARGET TEMP Service Holiday PROGRAM Clock Date OK New Check Clear End see 5 3 2 see 5 3 3 see 5 3 4 5 The holiday program is now programmed and is activated a...

Page 10: ...of the next day are dis played etc CHECK 7 6 5 4 3 2 1 PROG 6 00 0 3 6 9 12 15 18 21 24h 21 0 C END 3 sec Empty no program stored in memory back to Program see 5 3 1 OK OK back to Program see 5 3 1 CL...

Page 11: ...switch times 2 Clearing the desired switch times Clear All Empty no program stored in memory Confirm In order to cancel the clearing process press the ESC button back to Program see 5 3 1 OK OK OK ba...

Page 12: ...N T N N Actual temp N N T N N Program name T T T T T Table Overview of the information shown in the display for different display types 7 6 5 4 3 2 1 PROG 6 00 0 3 6 9 12 15 18 21 24h 21 0 C T text l...

Page 13: ...value with OK Cancel with ESC OK OK back to see 5 4 1 5 30 0 1 C 0 2 C Set with buttons or 0 2 C 5 0 C back to see 5 4 1 5 4 3 Selecting the language Select the language with the buttons or Confirm wi...

Page 14: ...e Month Weekend within month Hour for changeover e g from 2 a m to 3 a m Start of winter time Month Weekend within month OK Note Time for changeover to winter time is taken from summer time e g back f...

Page 15: ...K to 1 0 K hysteresis control Memory spaces 22 temperature changes programmable for Mo Fr Sa Su each day or for individ ual days Class of protection II according to EN 60730 1 Type of enclosure IP 20...

Reviews: