Note:
The time and date can also be changed in the "Service" menu
(see page 25). There you can also set the changeover from winter to
summer time.
4.5
Selecting the Temperature Profile
4.5.1
Program P1 (fixed program)
Comfort temperature Mo-Fr from 6 a.m. – 10 p.m. as
well as Sa-Su from 7 a.m. - 11 p.m. In between low-
er temperature.
4.5.2
Program P2 (fixed program)
Comfort temperature Mo-Fr from 6 - 8 a.m. and from 4 to 10 p.m. as
well as Sa-Su from 7 a.m. – 11 p.m. In between lower temperature.
4.5.3
Program P3 (freely programmable)
The program P3 is an individually programmable temperature profile.
Program P3 is not programmed when delivered. For programming
see page 22.
4.5.4
Permanent comfort
The room temperature is permanently regulated to the programmed
comfort temperature. There is no reduction.
4.5.5
Permanent reduction
The room temperature is permanently regulated to the programmed
lower temperature.
4.5.6
Antifreezing
The room thermostat only comes on when the room temperature falls
below the programmed antifreeze temperature.
4.6
Checking Current Room Temperature and
Settings - Info Button
With the
Info
button you can display the current room temperature as
well as all important settings of the program set at the rotary switch.
3. The display changes automatically to
the date setting.
Set the year, month and date one
after the other. Confirm each setting
with the
OK
button. The display
changes automatically.
4. The display automatically changes to the set automatic mode,
e.g. display of the target temperature.
OK
Year
2002
Month
04
OK
Day
09.04
OK
P2
P3
P1
MENU
1. Press the
Info
button. The current room temperature is shown in
the display for approx. 3 seconds. In order to continue with the
check, press the
Info
button again.
2. This way you can check the following information one after the
other:
-
Room temperature
-
Currently active target temperature
-
Date and time
-
Switch times of the set program (only visible with opened
hinged cover). The fixed programmed temperature profiles
and switch times are described in section 4.5.
4.5.4
Permanent comfort
The room temperature is permanently regulated to the programmed com-
fort temperature. There is no reduction.
4.5.5
Permanent reduction
The room temperature is permanently regulated to the programmed lower
temperature.
4.5.6
Antifreezing
The room thermostat only comes on when the room temperature falls
below the programmed antifreeze temperature.
4.6
Checking Current Room Temperature and
Settings - lnfo Button
With the
lnfo
button you can display the current room temperature as well
as all important settings of the program set at the rotary switch.
1. Press the
Info
button. The current room temperature is shown in
the display for approx. 3 seconds. In order to continue with the
check, press the
lnfo
button again.
2. This way you can check the following information one after the
other:
- Room temperature
- Currently active target temperature
- Date and time
- Switch times of the set program (only visible with opened hinged
cover). The fixed programmed temperature profiles and switch
times are described in chap. 4.5.
- Set display type, (i.e. which information is shown in the display,
also see chap. 5.4.2).
3. The check is completed. The display automatically switches back to
the original state.
4.7
Temporarily Changing the Target
Temperature
With this function, you can temporarily change the target temperature given
by the program. The changed target temperature is not saved long-term. It
only remains set until the next temperature change of the program (e.g. from
comfort to lower temperature).
Note:
If one of the programs “Perm. comfort”, “Perm. lower” or “Frost” is
set, the temperature change remains until the program changes.
1. Press one of the buttons
▲
or
▼
.The display shows the set target
temperature.
2. Change the target temperature with the buttons
▲
or
▼
.
3. After approx. 3 seconds, the display automatically switches back to
its original state, and the room thermostat regulates to the changed
target temperature.
4.8
Early Cancellation, Check or Clearance of
the Holiday Program
If you want to cancel an activated holiday program early, you must clear the
holiday program.
Note:
The setting of the holiday program is described in section 5.1.
28
ENGLISH