7
6. Technical Data
Operating voltage:
230 V AC +10 % / –15 %
Frequency:
50–60 Hz
Standby:
0,4 W
Max switching capacity.:
16 A (at 250 V AC, cos
ϕ
= 1)
Switching capacity:
10 A (at 250 V AC, cos
ϕ
= 0,6)
Min. switching capacity:
10 mA/230 V AC
100 mA/24 V AC/DC
Switch output:
switching of any phase is per-
mitted (SELEKTA 174 top3)
SELEKTA 170 top3:
suitable for switching SELV (Safe
Extra-Low Voltage)
Protection rating:
IP 20 in accordance with EN
60529
Protection class:
II in accordance with EN
60730-1 subject to designated
installation
Operating temperature:
–30 °C … +55 °C
Power reserve:
10 years at +20 °C (without
Bluetooth OBELISK top3)
Switching accuracy:
accurate to the second
Time accuracy (typical)
± 0,25 s/day (25 °C)
Rated impulse voltage
4 kV
Pollution degree
2
Contact
two way switch, contact µ
Max. switching cycles with 16 A resistive
load
50 000
Incandescent lamp load
2600 W
Halogen lamp load
2600 W
Fluorescent lamps (LLB low-loss bal-
lasts):
uncorrected
series-corrected
parallel-corrected
2600 VA
2600 VA
1300 VA (130 µF)
Compact fluorescent lamps (EB)
1100 W
LED-lamps (< 2 W)
50 W
LED-lamps (> 2 W)
600 W
Bluetooth OBELISK top3:
– Protection rating:
– Temperature:
– Range:
IP 40
–30 °C to +55 °C
15 m on open air test site
L
The time switch display is only fully functional at tempera-
tures from +5 °C - +55 °C.
7. Contact
Theben AG
Hohenbergstr. 32
72401 Haigerloch
GERMANY
Tel. +49 7474 692-0
Fax +49 7474 692-150
Hotline
Tel. +49 7474 692-369
Addresses, telephone numbers etc.
www.theben.de