background image

GENERAL INFORMATION

The timing capacity is 100 hours to 1 second. The unit 

may be set to count down and alarm, or count up and 

alarm. A “thru-zero” feature counts to the programmed 

time, alarms, and counts up. A memory function recalls 

the last programmed time. An audible alarm sounds for 

one minute when a programmed time is reached. A visual 

alarm flashes constantly until manually turned off. A time

-

out feature allows the timer to be stopped for “off” periods 

and restarted. The clock mode displays time-of-day to the 

second, has a time-of-day alarm, and sounds an hourly 

signal.

COUNT DOWN ALARM TIMING

1.  Press the MODE key until TMR appears on the dis-

play. If the timer is running, press the STOP key to 

stop the timer. Press the RESET key to clear the dis-

play to zero. Press the (▲▼) key until ▼ appears on 

the display (▼ indicates count down timing).

2.  Press the number keys 0 through 9 to set desired 

hours, minutes and seconds. Example: to set 89 

hours, 53 minutes, 27 seconds—press 8,9,5,3,2,7. 

Example: to set 12 minutes, 32 seconds—press 

1,2,3,2. Example: to set 58 seconds—-press 58.

3.  When the desired amount of time appears on the 

display, press the START key to begin timing down.

4.  When the timer reaches zero an electronic tone will 

sound and the display will flash TIME’S UP. The tone 

will sound for one minute and then turn oft automatical-

ly to preserve battery life. To turn the audible alarm off 

manually, press any key. At zero the timer begins tim-

ing up. This feature displays the amount of time which 

has elapsed since zero. When the alarm is sounding, 

the first press of any key turns off the electronic tone. 

Then press the STOP key to stop the UP timing. Press 

RESET to clear the display: The timer will only clear 

when time is stopped.

CORRECTING AN ENTRY

If an error is made during an entry, press the RESET key 

to clear the display to zero. If you wish to clear an entry 

when time is running, you must first stop the timing by 

pressing the STOP key, then press the RESET key. The 

timer will only clear when time is stopped.

COUNT UP ALARM TIMING

1.  Press the MODE key until TMR appears on the display. 

If the timer is running, press STOP to stop the timer. 

Press the RESET key to clear the display to zero. 

Press the (▲▼) key until ▲ appears on the display 

(▲ indicates count up timing).

2.  Press the number keys 0 through 9 to set desired 

hours, minutes and seconds. Example: to set 89 hours, 

53 minutes, 27 seconds—press 8,9,5,3,2,7. Example: 

to set 12 minutes, 32 seconds—press 1,2,3,2. 

Example: to set 58.

3.  When the desired amount of time appears on the dis-

play, press the START key to begin counting up.  

The timer automatically starts at zero and begins count-

ing up.

4.  When the programmed time is reached an electronic 

tone will sound and the display will flash TIME’S UP. 

The tone will sound for one minute and then turn 

off automatically to preserve battery life. To turn the 

audible alarm off manually, press any key. When the 

programmed time is reached, the display returns to zero 

and begins timing up. This feature displays the amount 

of time which has elapsed since the programmed time 

has been reached. When the alarm is sounding, the 

first press of any key turns off the electronic tone. Then 

press the STOP key to stop the UP timing. Press the 

RESET key to clear the display. The timer will only clear 

when time is stopped.

MEMORY FUNCTION (Count Down or Up Timing)

When timing repetitive intervals, the memory function will 

recall the last programmed time. It allows the user to dedicate 

the timer to a frequently timed test. The timer will return to the 

desired time period again and again.
Set a programmed time in either up or down timing. Press 

START. When the alarm sounds, press any key to stop the 

tone from sounding. Press the STOP key to stop the dis-

play from counting up. Press the MEMORY key to display 

the original programmed time. Press the START key to 

begin a memory time.
You may repeat this process as often as needed. Note: 

If RESET is pressed when the time is stopped, it clears 

the display and the memory.
You may view the time in the memory while the timer is 

running by holding down the MEMORY key. When the 

MEMORY key is released, the display returns to the 

running time.

TIMEOUT

The timer may be stopped during any running time by 

pressing the STOP key. Timing may be resumed by 

pressing the START key.

STOPWATCH TIMING

1.  Press the MODE key until TMR appears on the 

display. If the timer is running, press STOP to stop 

the timer. Press the RESET key to clear the display 

to zero. Press the (▲▼) key until ▲ appears on 

the display (▲ indicates count up timing).

2.  Press the START key to start timing. The timer may 

be stopped by pressing the STOP key and restarted 

by pressing the START key (timeout function). When 

timing has been completed and the timer has been 

stopped, press the RESET key to clear the display 

to zero.

Reviews: