MONOLITH BASIN SYSTEM MANUAL    7

2

The timber blocking should be 

mounted

 at 

heights as shown below. This will provide 

su

ffi

cient support and will allow the Monolith to 

be 

installed

 to comply with the current ADA / 

ANSI regulations.

1

The wall section where the Monolith is to be fixed 

should be reinforced using 2” x 1

2

” timber blocking 

to provide the additional support that is needed.

3

The wall-finish (drywall, plywood etc) can now be 

fitted in the normal manner.

monolith c series

before you install / timber stud wall

It is recommended that a timber stud framework is constructed to support the Monolith using construction-

grade 2” x 4” 

studs

. This will leave enough void within the wall for the required services for the plumbing 

installation.
For maximum strength, it is better if the studs can be fitted at centers corresponding to the 

mounting

 points 

for the Monolith brackets. If this is not possible, then the wall must be strengthened as below.

19 1/2”

11 1/4”

Summary of Contents for MONOLITH C Series

Page 1: ...MONOLITH Basin System C Series installation maintenance ...

Page 2: ...s List 5 Technical Data 6 Before you Install 10 Installation 14 ADA Compliance 15 Operation 15 Maintenance 16 Cleaning 16 Repairs 17 Damage Prevention 17 Faucets 17 Soap Dispensers 18 Warranty contents 2 MONOLITH BASIN SYSTEM MANUAL ...

Page 3: ...ash Lab Monolith System C Series is a trough sink specific to wall mounted fixtures for one to four users The basin is constructed from solid surface material mounted on steel brackets and is well suited to commercial and public restrooms MONOLITH BASIN SYSTEM MANUAL 3 ...

Page 4: ...that you consult the Structural Engineer or General Contractor for advice on the most appropriate mounting method for your project The 90 3 user TSL MON C 90 is pictured for all examples in this guide For the most accurate bracket spacing guide please refer to the shop drawings for your project A Trough 1 B Angled mounting bracket 4 C Drainage funnel 3 D Drainage funnel gasket 3 E Drainage funnel ...

Page 5: ... 2 00 24 00 20 00 2 00 2 00 86 00 2 00 24 00 5 00 90 00 A A 34 00 15 00 30 00 30 00 15 00 20 42 FINISHED FLOOR LEVEL The 90 3 user TSL MON C 90 is used for all examples in this guide pleases consult the shop drawings for your project before installing For model specific dimensions please refer to the datasheet for your model TSL MON C or download one at thesplashlabusa com ...

Page 6: ...ll be mounted 3 Cut a saw kerf width slot in the face of one of the sections of plywood to accept the flange on steel studwork as shown Fix the plywood to the steel stud using appropriate wall construction hardware The second layer of plywood is now to be fitted to the back of the 1st piece using flat head woodscrews at 6 centers monolith c series before you install steel stud wall The wall structure...

Page 7: ...eeded 3 The wall finish drywall plywood etc can now be fitted in the normal manner monolith c series before you install timber stud wall It is recommended that a timber stud framework is constructed to support the Monolith using construction grade 2 x 4 studs This will leave enough void within the wall for the required services for the plumbing installation For maximum strength it is better if the s...

Page 8: ... appropriate trap is required to connect to the 1 NPT thread on the waste funnel The trap should conform to the current local plumbing codes 3 Water supply pipes for wall mounted faucets should be within the wall void to best allow for connection P Trap Connection Waste Connection monolith c series before you install 3 User 90 Monolith ...

Page 9: ...s before you install 3 User 90 Monolith Fasteners 3 8 x 2 Lag screws 2 per bracket Required materials not included 1 1 2 NPT P trap 1 per user 1 1 2 drain piping to suit installation Plumbing 1 1 2 P Trap T M V Hot Feed ColdFeed Waste Water Hardware ...

Page 10: ...racket spacing guide please refer to the shop drawings for your project 3 User 90 Monolith 90 4 32 1 8 Length of trough No of Fixing height inches brackets Suggested bracket fixing centers Point A 20 to 36 Depending 20 to 36 Depending 20 to 36 Depending 4 00 TYP on sink design on sink design on sink design 4 00 TYP see sink drawings see sink drawings see sink drawings 34 TYPICAL 20 3 8 Starting poi...

Page 11: ...curely so that there will be no gap between the Monolith and the wall surface 1 Mark the bracket mounting points on the wall 3 Attach the brackets through the mounting slots with the lag screws using the height adjustment to ensure that all the brackets are all level and fitted at the same height It is critical that the brackets are level with one another to ensure that water drains properly out of...

Page 12: ...onolith placed face down fit all waste funnels and gaskets to the funnel adapter plates on the underside of the basin Install one bolt into each T slot pad Ensure that the sealing gasket is correctly fitted into the recess on the funnel and tighten the four bolts 7 When the Monolith T slot pads are resting on the brackets slide the Monolith towards the wall until the rear edge is flush with the wal...

Page 13: ...MONOLITH BASIN SYSTEM MANUAL 13 monolith c series installation 9 Fit waste trap to drain funnel ...

Page 14: ...14 MONOLITH BASIN SYSTEM MANUAL monolith c series ADA compliance 24 00 17 85 14 66 5 00 38 00 34 00 29 00 27 00 9 00 11 00 6 00 ADA KNEE AND FOOT CLEARANCE ZONE 17 00 7 00 ...

Page 15: ...cet or a manual faucet allow the water to flow and wash their hands in the normal manner maintenance The Monolith should be periodically inspected for any damage Also the Monolith should be tested to ensure that the water drains out of the basin and that the drainage waterways are not blocked with any debris ...

Page 16: ...leaners and a white abrasive pad or sponge For darker colors a polish may be used to enhance the shine For areas where there is the possibility of contact with food a polish formulated for use in food contact areas must be used Where food contact is not likely to occur a simple furniture polish can be used Always follow the manufacturer s instructions for using the polish and for safety concerns C...

Page 17: ...ents should be promptly flushed with water Contact for even a short period of time can cause surface damage spots or staining Follow the recommended repair procedures described above as needed to repair and or restore the surface to its original condition Severe damage caused by incompatible chemical contact will require professional repair Again contact The Splash Lab technical department for assi...

Page 18: ...d product 10 years for material used If a defect is found in normal use The Splash Lab will at their discretion repair provide a replacement part or product or make appropriate adjustments Damage caused by accident misuse or abuse is not covered by this warranty Improper care and cleaning will void the warranty Non operation of the product due to environmental conditions beyond our control install...

Page 19: ... 15 21 General information 310 410 5008 Showroom 8745 Washington Boulevard Studio D Culver City CA 90232 Warehouse Offices 20809 Higgins Court Torrance CA 90501 Technical support info thesplashlabusa com For further contact information visit www thesplashlabusa com ...

Reviews: