The No. 12B Transformer
is a
Dual Transformer. I t has two control
levers and two corresponding sets of
three terminals, as shown in Fig. 17.
Each throttle operates separately, thus
permitting the operation of two or more
trains simultaneously on two sections of
"A"
layout as shown in Fig. 18.
AMERICAN FLYER TRANSFORMER DATA
Transformer
A.
C.
Variable Volt-
No.
Voltage
Capacity
Frequency
age Range
Fixed Voltage
1
115
25 Watts
60
Cycles
7-15 Volts
2
115
75
“
60
“
7-15
“
15 Volts
4B
115
100
“
60
“
7-15
“
15
“
8B
115
100
“
60
“
7-15
“
15
"
12B
115
250
“
60
“
7-15
“
15
“
19B
115
300
“
60
“
7-15
“
15
“
T O CHECK T H E TRANSFORMER. Press Reset Button to be sure
it is down. Turn the lever half on. Connect one end
of
a
piece of wire to the
Base Post and touch the
7
to 15 volt Post very lightly with the other end.
(DO NOT HOLD T H E WIRE
ON
T H E 7-15 VOLT POST.
JUST
TOUCH
IT LIGHTLY.) If a spark occurs the transformer is
O.K.
If
no spark occurs
the transformer is defective unless the fault is at the wall socket which can
be checked by plugging in
a
bridge lamp.