Troubleshooting (cont.)
Symptoms
Probable Causes
Recommended Action
D.
One or both of the limit
switches are not making contact
or are damaged.
D1.
Adjust the limit switch/switches
until contact is made.
D2.
The limit switch/switches need to
be replaced. Call the Customer
Care Center using the information
provided on the back page of this
manual.
E.
The drain valve is connected to
another 120 V outlet and/or is
not plugged into the controller.
E.
Plug the drain valve directly into J2
in the controller.
F.
Error code in controller has
been activated (beeping sound
heard).
F1.
Reset the controller. To do this;
lower the door
quickly tap the door switch 5
times
wait 3 seconds, then tap the
switch 11 times within a 5
second span
the controller should beep 3 to
5 times to indicate the issue
has been resolved, then go
quiet.
F2.
If the error code is still activated or
reoccurs, unplug the power and
call the Customer Care Center
using the information provided on
the back page of this manual.
G.
The drain valve is not working.
G.
Replace the drain valve or call the
Customer Care Center using the
information provided on the back
page of this manual.
H.
The controller is not working.
H.
Replace the controller or call
Customer Care Center using the
information provided on the back
page of this manual.
11.
The seal will not fully
inflate or the compressor
keeps turning on after
inflation.
A.
One or both limit switches are
not making contact or are
damaged.
A1.
Adjust the limit switch or switches
until contact is made.
A2.
The limit switch needs to be
replaced. Call the Customer Care
Center using the information
provided on the back page of this
manual.
B.
The primary seal system is not
operating properly or the air
line might be pinched.
B.
Call the Customer Care Center
using the information provided on
the back page of this manual.
C.
There is air leaking inside the
door.
C.
Call the Customer Care Center
using the information provided on
the back page of this manual.
D.
The air pressure switch is not
working or is leaking air.
D.
The air pressure switch needs to be
replaced. Call the Customer Care
Center using the information
provided on the back page of this
manual.
1128535-5-G
16
Kohler Co.