Appendix C: IPMI
DSM IPMI CLI Commands
DSM Installation and Configuration Guide
Copyright 2009 - 2020 Thales Group. All rights reserved.
168
SUCCESS: user privilege level modified
clearint
Clear chassis intrusion. When someone opens the chassis cover of the DSM, chassis intrusion will get flagged. When
the cover is put back, run
clearint
to clear it.
Syntax
clearint
Example
clearint
SUCCESS: Clear chassis intrusion flag
psinfo
Show power supply information. If only one power module is plugged in, the output will display only one module.
Syntax
psinfo
Example
0001:ipmi$ psinfo
[SlaveAddress = 78h] [Module 1]
Item
|
Value
----
|
-----
Status
|
[STATUS OK](00h)
AC Input Voltage
|
116.5 V
AC Input Current
|
0.34 A
DC 12V Output Voltage
|
12.00 V
DC 12V Output Current
|
2.25 A
Temperature 1
|
27C/81F
Temperature 2
|
34C/93F
Fan 1
|
5472 RPM
Fan 2
|
0 RPM
DC 12V Output Power
|
26 W
AC Input Power
|
36 W
PMBus Revision
|
0x8B22
PWS Serial Number
|
P406PCE24AT1144
PWS Module Number
|
PWS-406P-1R
PWS Revision
|
REV1.1
[SlaveAddress = 7Ah] [Module 2]
Item
|
Value
----
|
-----
Status
|
[STATUS OK](00h)
AC Input Voltage
|
117.0 V
AC Input Current
|
0.37 A
DC 12V Output Voltage
|
12.00 V
DC 12V Output Current
|
2.87 A
Temperature 1
|
35C/95F
Temperature 2
|
40C/104F
Fan 1
|
6560 RPM
Fan 2
|
0 RPM
DC 12V Output Power
|
36 W
AC Input Power
|
43 W