BATTERY CHARGERS
Doc No. 84382 Rev 2
THALES COMMUNICATIONS, INC. PROPRIETARY INFORMATION
5-3
OPERATING INDICATIONS
All versions of the chargers use LEDs to indicate the current charging status and/or charging problems.
The meanings of the LED’s are as follows:
Table 5-6 Single-Bay Charge Status Indicators
Description
Indication
The charger will display a flashing yellow/green LED indication while it
attempts to establish communications with the battery.
FLASHING
YELLOW/GREEN
If the battery temperature exceeds its maximum operating temperature
the
charger shall set the status LED to solid RED
RED
If the battery status indicates an over-discharged condition, the charger shall
set the status LED to flashing RED
FLASHING RED
If the battery temperature is below 0°C, the charger shall set the status
LED
to flashing YELLOW.
FLASHING YELLOW
During charging, the charger shall set the status LED to solid Yellow.
YELLOW
When charging is > 90%, the charger shall set the status LED to GREEN.
GREEN
When a battery/charger error is detected, the charger shall set the status LED
to flash RED/GREEN.
FLASHING
RED/GREEN
When a Charger error condition is detected, the charger shall set the status
LED to flashing YELLOW/RED.
FLASHING
YELLOW/RED
CAUTION
Do not insert a new battery in the charger until
the LED is turned off.
!
NOTE
If a battery is inserted in the charger while attached to a
radio and the radio is ON, the radio fuel gauge may indicate
that the battery is fully charged before the charger indicates
full charge.
!
NOTE
The battery can be charged while attached to a radio.