Datacryptor Ethernet User Manual
Appendix I: Log and SNMP Trap Numbers
1270A450-005 - June 2008
Page 125
Log Type
Code
Trap
No.
Severity Message
Information
Audit
46
733
Major
Keylock moved to Transport
Audit 47
734
Major
Keylock
moved
from
Transport
Audit
48
735
Major
Keylock moved to Erase
Audit
49
736
Major
Keylock moved from Erase
Audit 50
744
Informational
Tunnel
SA
Added
Audit 51
745
Informational
Transport
SA
Added
Audit
59
746
Informational Set Private Network
Audit
60
747
Informational Set Private Address
Audit
61
748
Informational Set Public Address
Audit
62
749
Informational Default mode is Discard
Audit
63
750
Informational Default mode is Passthrough
Audit
64
751
Informational Trunk SA Added
Trunk Mode not
supported by Datacryptor
AP
Audit 65
752
Informational
Tunnel
SA
Deleted
Audit 66
753
Informational
Transport
SA
Deleted
Audit
67
754
Informational Trunk SA Deleted
Trunk Mode not
supported by Datacryptor
AP
Audit 68
788
Informational
Force
Standby
on
boot
cleared
Audit
69
756
Informational Key Algorithms stored in
backup memory
Audit
70
757
Informational Key Algorithms recovered
from backup
Audit 71
758
Critical
Random
No.
Generator
diagnostics FAILED
This may be a "statistical
fail, i.e. as it is a random
number generator it may
fail the tests occasionally,
it is normally expected to
recover
Audit 72
759
Critical
Random
No.
Generator
diagnostics RECOVERED
Audit
73
760
Major
Primary mode failure: No
response from Private known
IP address
Hot standby unit detected
possible disconnection
from private network
Audit
74
761
Major
Primary Mode Failure: No
response from Public known
IP address
Hot standby unit detected
possible disconnection
from public network