Nominal Operating voltage:
12 or 24 VDC
(field changeable)
Motor current:
Nominal*
Limit
Elevation motor:
6 amps
15 amps
Horizontal rotation motor:
6 amps
10 amps
Nozzle motor:
1 amp
5 amps
*with rated water pressure applied
At rest current:
.25 amps
Recommended fuse or circuit breaker size:
15 amps @ 12 volts, 7.5 amps @ 24 volts
Operating temperature range:
-30°F to +120°F (-34°C to +49°C)
Environmental Rating: All components designed to meet minimum rating of NEMA 4 (IP65).
3.2 PART IDENTIFICATION AND MODELS
The Hurricane RC Monitor as shown in Figure 3.2 along with the names of some various parts and controls.
FIG 3.2
Part Identification
4
3.1.2 ELECTRICAL SPECIFICATIONS
BUILT IN
STREAM
STRAIGHTENER
ELEVATION DRIVE
HOUSING (SECT. 9.2)
HORIZONTAL
ROTATION TRAVEL
STOPS 5 PLACES
(SECT. 4.4)
AUTOMATIC
DRAIN
(SECT. 4.6 & 6.4)
OUTLET
(FIGURE 3.3)
GREASE ZERK
(SECT. 8.1)
PRODUCT NAME LABEL
WITH SERIAL# & MODEL #
POWER CABLE
ELEVATION
MOTOR (SECT. 9.3)
WIRE SKIRT/CABLE GUIDE
(SECT. 9.1)
INLET
(FIGURE 3.3)
STRAIGHT BACK
REFERENCE MARK
(SECT. 4.2)
PORT FOR
PRESSURE GAGE
(SECT. 4.5)
HORIZONTAL
ROTATION
HANDWHEEL
(SECT. 6.1)
ELEVATION
HANDWHEEL
(SECT. 6.1)
CONTROL STATION BOX
WITH CONTROL BUTTONS
(SEE SECT. 6.2.1.1)
GREASE ZERK
(SECT. 8.1)
HORIZONTAL
MOTOR
(SECT. 9.3)
Handheld Unit Batteries
Transmitting Power
Operating Range
Operating Frequency
Four (AA) Batteries, Lithium Recommended
100mW
50mW
500 ft (152m)
Agency Approvals
FCC. . . . . . . . . . . . . . . . . . . . . . . OUR9XSTREAM . . . . . . . OUR24XSTREAM
Industry Canada (IC) . . . . . . . . . 4214A-9XSTREAM . . . . . . . . 4214A-12.008
Europe . . . . . . . . . . . . . . . . . . . . . . . . . . N/A . . . . . . . . . . . . . . . . . . ETSI
YE-RF-900, 900 MHz
YE-RF-2400, 2.4 GHz
900 MHz
(902-928 MHz)
2.4GHz
(2.4000-2.4835 GHz)
Wireless Operator Station (YE-RF-##)