background image

 

 

 

11 

6. Supply scope 

 
 

Name 

Qty 

Note 

TFortis SG-Switch lightning protection device 
Components: 

  Ethernet module (ESG) 

– 5. 

  230 V module (PSG) 

– 1. 

 

Cable gland 4-8 mm (PG9) 

13 

 

Product certificate 

 

 
 
 
 

7. Manufacturer's warranty 

 
The warranty period for the switch is 36 months from the date of sale. Only 
a complete switch is accepted for servicing and repair. 
Warranty shall not apply in the following cases: 

  if the warranty period has expired; 

  if  manufacturer's  marking  with  the  serial  number  on  the  housing  is 

missing  or  if  the  serial  number  has  been  changed,  removed  or  is 
illegible; 

  if  there  are  internal  of  external  mechanical  damages  (chipping, 

cracking,  deformation,  damaged  power  supply  wires,  cracking  or 
splitting  of  the  terminals),  signs  of  treatment  with  aggressive 
chemicals or fluids, severe contamination, insects presence or signs 
of insects presence; 

  in case of improper connection and operation of the switch or if power 

supply  parameters  do  not  meet  the  requirements  specified  in  this 
operating manual; 

  if  the  switch  was  damaged  as  a  result  of  force  majeure,  due  to  the 

actions  of  third  parties  or  other  reasons  beyond  manufacturer's 
control. 

Summary of Contents for SG-Switch

Page 1: ...1 Operating Manual TFortis SG Switch Surge protection unit for TFortis PSW switches Version 3...

Page 2: ...Switches The specified technical parameters are guaranteed for the protection of TFortis PSW switches manufactured starting 07 2017 Grounding of the switch is obligatory It is recommended to check the...

Page 3: ...ose 4 2 Description 5 3 Technical parameters 7 4 Operating conditions 8 5 Installation 8 5 1 Housing installation 8 5 2 Connecting power supply 9 5 3 Connecting the twisted pair 10 6 Supply scope 11 7...

Page 4: ...f TFortis PSW switches up to class 5 according to GOST R 51317 4 5 Figure 1 Typical application scheme Features High level of protection against lightning interferences class 5 All weather performance...

Page 5: ...R 51317 4 5 performance criterion B Since July 2017 all TFortis PSW switches are manufactured with improved lightning protection class 4 according to GOST R 51317 4 5 TFortis SG Switch increases the...

Page 6: ...of parallel installation of power cables and signal cables Class 4 Electromagnetic environment in case of installation of connecting cables outdoors in the proximity of power cables and using multi wi...

Page 7: ...uctors are protected by the twisted pair Protects Ethernet ports of TFortis PSW switches from powerful pulse interferences 4 kV 6 5 700 s based on the wire ground scheme with performance criterion B G...

Page 8: ...n and immediately after the storm 5 Installation 5 1 Housing installation The housing has four attachment points at the edges Marking of the attachment points is shown in Figure 3 Figure 3 Attachment...

Page 9: ...of the terminals when connecting the power cable to 230 VAC protection module Terminal IN 230 VAC input for connecting the power supply cable Terminal OUT 230 VAC output for connecting to TFortis PSW...

Page 10: ...6 Connection of the Ethernet cable When the lightning protection device SG Switch is located in the same cabinet wit TFortis PSW switch it is allowed to use a non shielded twisted pair between these...

Page 11: ...ial number on the housing is missing or if the serial number has been changed removed or is illegible if there are internal of external mechanical damages chipping cracking deformation damaged power s...

Reviews: