19
Duplex Insertion Loss Test – 850/1300
Continued. . .
TO CONTINUE TESTING ADDITIONAL FIBERS -
17. Press the AutoTest button to return to the AutoTest screen. If the
previous test was saved, the fiber numbers will automatically
sequence up. (i.e. Fiber 001 & 002 changes to 003 & 004)
18. To begin the AutoTest sequence, press the AutoTest button on the
unit.
19. The screen will indicate the connections to be made – Fiber 003 to
the transmitter & Fiber 004 to the receiver.
20. Clean all interfaces and connect the patch cables to the Fiber Under
Test.
21. Press the AutoTest button on the unit again to begin testing.
NOTE:
I
F
A
UTOTEST OR
R
EFERENCE
F
AILS TO
C
OMPLETE
-
1. Check all connections for correctness and cleanliness.
2. Ensure Link Loss is <30dB at both 850/1300nm.
3. Keep Remote unit in Startup screen. (Duplex IL 850/1300)
4. Ensure reference step has been completed.
Section 2: Quick Start Guide