HE.15323_C © 06/2014
5
AHP 850-LC
GB
Instruction Manual Battery-hydraulic Pump
authorised
copy
The tool is not designed for continued operations. After a sequence of approximately 100 completed cycles you have
to make a break of 15 min. to give the tool time to cool down.
Attention
Too intensive use can cause heat damages for the tool
Attention
During the operation of electric engines sparks can occur which might ignite highly infl ammable or explosi-
ve liquids and materials
Attention
Electric-hydraulic tools should not be operated in pouring rain or under water.
The tool can be operated in a temperature range of -12°C bis +40°C inside as well as outside.
3.3 Oil changing and maintenance cycles
For every day service the tool has to be cleaned and dried after each use. The battery cartridge and the charging unit
have to be protected against humidity and dust.
The pump has an oil plug with inspection glass which can be used to determine the proper oil level. If the oil level
should be too low the reservoir must be refi lled.
The following hydraulic oils are suitable for a temperature range -12°C to +40°C:
Hydraulic oils based on Ester:
Rivolta S.B.H. 11, Shell Naturell HF-E 15
Mineral oils:
Shell Tellus T 15, AVIA HVI 15, Mobil DTE 11, NUTO H 15, Rando HD - Z15, Agip OSO 15, BP Energol
HLP 15.
Other equivalent hydraulic oils can also be used.
The hydraulic hose and the armature must be checked for damage and leakage.
Attention
Maintain power tools thoroughly. Check for functionality or jamming of moving parts, breakage of parts and
any other condition that may affect the power tools operation.