HE.15323_C © 06/2014
7
AHP 850-LC
GB
Instruction Manual Battery-hydraulic Pump
authorised
copy
Attention
Spilled hydraulic oil has to be absorbed immediately.
3.4 Reference as to which spare parts can be exchanged by the customers
Within the determined use of the tool the customers may only change the oil.
Attention
Do not damage the seals of the pump.
Do not attempt to repair the tool yourself, and do not remove any parts such as screws and other components.
4. Troubleshooting
a.) Constant fl ashing/indicating of the red LED.
see tab. 2. If the failure can not be resolved through the action recommended in tab. 2 return the unit to the
nearest service center (ASC).
b.) The tool or the crimping head loses oil.
Return the unit or the accessories to the manufacturer. Do not open it and damage the seal of the tool.
5. Technical Data
Protective system:
IP 43
Driving motor:
direct-current permanent fi eld
max. operation pressure:
850 bar
Weight of the unit: approx. 4,9 kg
Hydraulic oil:
Rivolta S.B.H. 11
Battery voltage:
18 V
Reservoir capacity:
approx. 760 ml
Battery capacity:
4 Ah (RAL40/BL1840)
Useable oil capacity:
approx. 740 ml
Charging time:
36 min. (RAL40/BL1840)
Environmental temperature: -12°C bis +40°C
Sound level:
< 70 dB (A) in 1m distance
Control voltage:
18 V DC
Vibrations:
< 2,5 m/s²
Remark
Additional instruction manuals are available free of charge. The part # is HE.15323.
The Instruction Manual can also be downloaded from our Homepage www.klauke.textron.com.