background image

H4905A Hydraulic Sign Post Puller

Greenlee / A Textron Company

4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070

7

Specifications

Sign Post Puller

Type of Hydraulic System:  Open-center
Hydraulic Ports:

Pressure (supply):  9/16–18 SAE O-ring boss
Tank (return):  3/4–16 SAE O-ring boss

Lifting Force:  43.6 kN (9800 lb)
Stroke:  127 mm (5")
Sound Power Level:  32 L

wa

Mass/Weight:  32 kg (70 lb)
Height:  660 mm (26")
Width:  254 mm (10")
Length:  267 mm (10.5")

Hydraulic Power Source

Do not exceed the following hydraulic power source 

maximums:

Hydraulic flow:  22.7 l/min (6 gpm)

• 

Pressure relief:  138 bar (2000 psi)

• 

Back pressure:  13.8 bar (200 psi)

• 
Failure to observe this warning could result in severe 

injury or death.

Type of Hydraulic System:  Open-center
Flow:

Minimum:  15.1 l/min (4 gpm)
Recommended:  18.9 l/min (5 gpm)
Maximum:  22.7 l/min (6 gpm)

Filtration:  10 micron (nominal)
Pressure Relief Setting:  138 bar (2000 psi)
Back Pressure (maximum*):  13.8 bar (200 psi)
    *  13.8 bar (200 psi) is the maximum agreed stan-

dard back pressure for the HTMA (Hydraulic Tool 

 Manufacturers Association). Greenlee Utility tools 

will  operate satisfactorily at this standard.

1.  Maximum hydraulic fluid temperature must not 

exceed 60 °C (140 °F). A sufficient oil cooling 

capacity is needed to limit the hydraulic fluid 

 temperature.

2.  Hydraulic flow must not exceed 22.7 l/min (6 gpm). 

Install a flow meter in the return line to measure the 

rate of hydraulic flow before using the tool.

3.  Pressure relief valve setting must not exceed 

 

138 bar (2000 psi) at your tool’s maximum flow. 

Locate the pressure relief valve in the supply circuit 

to limit excessive hydraulic pressure to the tool.

Hydraulic Schematic

FILTER

(10 micron)

COOLER

RELIEF

VALVE

138 bar

(2000 psi)

CONTROL

VALVE

FLOW METER

T

P

TOOL

RESERVOIR

PUMP

POWER SOURCE

Recommended Hydraulic Fluids

Use any nondetergent, petroleum-based hydraulic 

fluid which meets the following specifications or HTMA 

specifications.
S.U.S. @:

38 °C (100 °F):  140 to 225
99 °C (210 °F):  40 minimum

Flash Point:  170 °C (340 °F) minimum
Pour Point:  –34 °C (–30 °F) minimum

Summary of Contents for Greenlee H4905A

Page 1: ...ulic Sign Post Puller 99936755 REV 3 2010 Greenlee Textron Inc 1 10 Read and understand all of the instructions and safety information in this manual before operating or servicing this tool Register t...

Page 2: ...ed to familiarize personnel with the safe operation and maintenance procedures for the following Greenlee Utility tool H4905A 42237 Sign Post Puller Keep this manual available to all personnel Replace...

Page 3: ...lt in severe injury or death Electric shock hazard This tool is not insulated Do not use this tool near energized electrical lines Failure to observe this warning could result in severe injury or deat...

Page 4: ...lb minimum breaking strength An underrated chain may break during operation Failure to observe this warning could result in severe injury or death Do not exceed the following hydraulic power source m...

Page 5: ...ended purpose only Use other than that which is described in this manual may result in injury or property damage Make sure all bystanders are clear of the work area when handling starting and operatin...

Page 6: ...n Company 4455 Boeing Dr Rockford IL 61109 2988 USA 815 397 7070 6 Identification 1 Base 2 Chain 3 Serrated Jaws 4 Cylinder 5 Handle 6 Guide 7 Serial Number 8 Bracket 9 Control Lever 10 Pressure suppl...

Page 7: ...8 bar 200 psi 13 8 bar 200 psi is the maximum agreed stan dard back pressure for the HTMA Hydraulic Tool Manufacturers Association Greenlee Utility tools will operate satisfactorily at this standard...

Page 8: ...ing Hoses 1 Move the flow lever on the hydraulic power source to the OFF position 2 Stop the hydraulic power source 3 Connect the tank hose to the tank return port on the hydraulic power source and th...

Page 9: ...s connected to a power source Accidental start up can result in serious injury Failure to observe this warning could result in severe injury or death Make sure all bystanders are clear of the work are...

Page 10: ...ection when operating or servicing this tool Failure to wear eye protection could result in serious eye injury from flying debris or hydraulic oil Do not change accessories inspect adjust or clean too...

Page 11: ...the fluid level Check system for leaks Air in the hydraulic system Refer to the power source manufac turer s instructions for removing air from the system Incorrect hydraulic fluid viscosity Use hydr...

Page 12: ...ng Dr Rockford IL 61109 2988 USA 815 397 7070 12 Illustration 24 43B 43A 18 19 41 30 37 40 29 28 27 38 39 42 36 28 26 31 32 31 34 35 30 12 11 10 7 33 9 8 2 54 24 53 21 20 14 15 1 6 3 4 9 9 5 50 22 49...

Page 13: ...7 43151 50431510 Spool 1 28 O ring 437 x 562 x 062 70 2 29 40258 50402582 Lever bracket 1 30 Screw cap 1 4 20 x 500 socket head 8 31 43429 50434292 Washer flat 265 x 734 x 059 2 32 43836 50438360 Spac...

Page 14: ...ax 815 397 1865 Canada 800 435 0786 Fax 800 524 2853 International 1 815 397 7070 Fax 1 815 397 9247 4455 Boeing Drive Rockford IL 61109 2988 USA 815 397 7070 An ISO 9001 Company Greenlee Textron Inc...

Reviews: